Folktandvården Majorna

Passage (Trappa/hiss)

Indoor environment
  • Lights
  • The sound environment is noise free
  • The sound has a long lingering note
  • The lighting is blinding
  • The lighting is even
  • Means for screening off glaring daylight are not available
  • Cleaning products are not perfumed
  • The room is cleaned 5 per week
  • Wall-to-wall textile carpet are not available
Assistance dogs
  • No assistance dog allowed
  • No assistance dog is/are allowed in the space
Walking area
  • Walking area
  • A walking area is hardened, even
  • The walking area is 193,1cm wide
  • Space where it is possible to turn around is available
  • A walking area is hardened, even
  • The walking area is 193,1cm wide
  • The stairs are compensated by lift
Stairs
  • Stairs
  • There is 9st steps to the resting level
  • The stairs are straight
  • The stairs are 126,3cm wide
  • The bottom step has a contrast marking of 0NCS
  • The stair steps are 14,5cm high
  • The top step has a contrast marking of 0NCS
  • Depth of staircase steps is 32,3cm
  • The staircase is hardened, even
  • There are available protruding level steps
Handrail on right hand side as seen from below
  • Right banister
  • The height of the handrail is 97,6cm
  • The handrail extends 0cm past the part
  • Handrail stops 0cm before the bottom end
  • There available a handrail that ends abruptly at the lower part
  • There available a marking lower part at the end of handrail
  • The handrail extends 0cm past the part
  • The handrail ends 0cm before the top part
  • There available a handrail that ends abruptly at the upper part
  • There available a marker at the end of the handrail at the top
  • The brightness contrast of the handrail is 0,43NCS against the background
  • There not available a handrail which runs continuously
Handrail on left hand side as seen from below
  • Left banister
  • The height of the handrail is 98,2cm
  • The handrail extends 300cm past the part
  • Handrail stops 0cm before the bottom end
  • There not available a handrail that ends abruptly at the lower part
  • There available a marking lower part at the end of handrail
  • The handrail extends 300cm past the part
  • The handrail ends 0cm before the top part
  • There not available a handrail that ends abruptly at the upper part
  • There not available a marker at the end of the handrail at the top
  • The brightness contrast of the handrail is 0NCS against the background
  • There available a handrail which runs continuously
Gateway
  • Width of the passage opening
  • The free width of the door opening is 129,1cm
  • The door frame has a lightness contrast of 0,93NCS against the surrounding wall
Lift
  • The elevator buttons
  • Turning space
  • The elevator floor
  • The call button is placed 106,8cm above the ground
  • The distance to the nearest object is 170cm
  • The lightness contrast of the function is 0,40NCS against the background
  • The function is press button
  • The length of the free space is 169,3cm
  • The width of the free space is 300cm
  • The lift car is 144,9cm deep
  • The lift car is 109,9cm wide
  • The difference in level between the lift floor and the area outside is 3mm when the lift has stopped
  • Handrail is available on the same side as the control panel
  • The handrail has a lightness contrast of 0NCS
  • The handrail is 86,2cm above the floor
  • Lift that opens out onto a descending staircase is not available
Swing door
  • The doors width
  • The free width of the door opening is 87,7cm
  • The door surface has a lightness contrast of 0,12NCS against the door frame
  • The door frame has a lightness contrast of 0,81NCS against the surrounding wall
  • The door frame has a lightness contrast of 0,81NCS against the surrounding wall
Swing door opens manually
  • Manual door
  • The door handle is placed 136,1cm from the nearest obstacle
  • Door closer is available on the door
Swing door opens with switch for door opener
  • Actuator
  • Actuator on the inside of the elevator
  • The switch for the door opener outside the door is placed 120,9cm above the floor
  • The switch for the door opener outside the door is placed 300cm from the nearest obstacle
  • The switch for the door opener outside the door has a lightness contrast of 0,55NCS
  • Door which opens out into area where people pass is not available
  • Marking of the area covered by the door as it opens up, is not available that can be felt with a white cane
  • The lightness contrast of the area where the door opens up is 0NCS
  • The switch for the door opener inside the door is placed 105,7cm above the floor
  • The switch for the door opener inside the door is placed 65cm from the nearest obstacle
  • The switch for the door opener inside the door has a lightness contrast of 0,63NCS
Opening up
  • No securitty sensor
  • Security sensor is not available for when the door opens
Closing
  • No security sensor
  • Passage time of the elevator door
  • Security sensor is not available for when the door closes
  • The passage time is 14s
Control panel in lift
  • The elevator buttons on the inside
  • The lift buttons are 6,5cm large
  • The type of lift buttons is raised
  • The lift buttons have neither relief nor braille as a tactile marking
  • Lift button not available which needs to be held in for the duration of the ride
  • Emergency alarm that is placed on or next to the control panel are available
  • Visually marked button for emergency alarm is available
  • Tactile marking on button for emergency alarm is not available
  • Alarm instructions in easy to understand Swedish are not available
  • Alarm instructions in braille are not available
  • Alarm instructions as picture symbols are not available
  • A visual confirmation that the alarm has gone through is not available
  • An acoustic confirmation that the alarm has gone through is available
  • Emergency instructions in english are not available
Control panel in the lift
  • Actuator on the inside of the elevator
  • The upper row of buttons is placed 118cm from the floor
  • The lower row of buttons is placed 109,1cm from the floor
  • The distance between the manoeuvering panel and the corner by the door is 40cm
  • The manoeuvering panel is angled outward from wall from the wall
  • The lift button is angled outward from wall
Information about floors
  • Visual floor information
  • Visual information is available regarding the floor levels
Different businesses or activities on different floors
  • Sign with floor information
  • Sign with information about businesses and activities is available