Denna webbplats använder teknik som troligen inte stöds i din webbläsare, därför kan vissa saker se konstiga ut eller inte fungera. Vi rekommenderar att du byter till en modern webbläsare istället.
Skip to main content

Hotell Nordens Ark

Hoppa över karta

Contact

Uppdated
2/16/2016 5:36:19 AM
Address
Åby Säteri
456 93
Hunnebostrand
Telephone
+46 (0)523 79546
Home page
Views

Filter on your needs

Description of the site you are visiting

Print full site

Section heading

Print

Footpath

  • The pedestrian path is 300m wide
  • The surface of the pedestrian path is hardened
  • The walking area tilts 1,9% sideways
  • Lighting is available
  • Uncovered gutter is not available
  • The lengthways tilt is 6,3%
  • The length of the slope is 40m
  • The length of the area after the slope is 20m
  • The area after the slope tilts 0% sideways

The gateway

  • Lightness contrast sides of gateway against surrounding surfaces is 0,60NCS
  • The gateway is 300cm wide

Section heading

Print

Swing door

  • The turning space outside the door is 300cm wide
  • The length of the turning space outside the door is 300cm
  • The turning space outside the door tilts 0% sideways
  • The turning space outside the door tilts 0% lengthways
  • The free width of the door opening is 86cm
  • Lighting is available
  • The door surface has a lightness contrast of 0,45NCS against the door frame
  • The door frame has a lightness contrast of 0,30NCS against the surrounding wall
  • The door frame has a lightness contrast of 0,30NCS against the surrounding wall

Single colour marking on the glass surface at eye level for sitting

  • The marking is placed 90cm above the floor
  • The colour of the marking is brown
  • The marking is placed 90cm above the floor
  • The colour of the marking is brown

Single colour marking on the glass surface at eye level when standing

  • The marking is placed 145cm above the floor
  • The colour of the marking is brown
  • The height of the threshold is 3cm
  • The height difference to the bevelling is 1cm
  • The marking is placed 145cm above the floor
  • The colour of the marking is brown

Wiping grid inside door

  • The wiping grid is loose

Swing door opens manually

  • The door handle is placed 200cm from the nearest obstacle
  • Door closer is not available on the door

Entrance

  • Designated smoking area is available
  • A smoking area is not available that is placed so that smoke is avoided inside the building and by the entrance

Sign on wall

  • The sign lighting is non-blinding
  • The lower edge of the sign is placed 250cm from the ground
  • The upper edge of the sign is placed 300cm from the ground
  • The brightness contrast of the sign is 0,85NCS against the background
  • The sign has neither relief nor braille
  • The size of capitals is 50mm

Swing door in inner entrance

  • The turning space outside the door is 300cm wide
  • The length of the turning space outside the door is 462cm
  • The turning space outside the door tilts 0% sideways
  • The turning space outside the door tilts 0% lengthways
  • The free width of the door opening is 86cm
  • Lighting is available
  • The door surface has a lightness contrast of 0,45NCS against the door frame
  • The door frame has a lightness contrast of 0,30NCS against the surrounding wall
  • The door frame has a lightness contrast of 0,30NCS against the surrounding wall
  • The turning space inside the door is 300cm wide
  • The length of the turning space inside the door is 300cm
  • The turning space inside the door tilts 0% sideways
  • The turning space inside the door tilts 0% lengthways

Threshold

  • The height of the threshold is 4cm
  • The height difference to the bevelling is 2cm

Swing door in inner entrance opens manually

  • The door handle is placed 4cm from the nearest obstacle
  • Door closer is not available on the door

Section heading

Print

Indoor environment

  • The sound environment is noisy
  • The sound has a short lingering note
  • The lighting is non-blinding
  • The lighting is even
  • Occurring daylight is blinding
  • Means for screening off glaring daylight are not available
  • Cleaning products are not perfumed
  • The room is cleaned 7 per week
  • Wall-to-wall textile carpet are not available
  • The evacuation alarm is audible

Single colour marking on the glass surface at eye level for sitting

  • The marking is placed 85cm above the floor
  • The colour of the marking is white

Single colour marking on the glass surface at eye level when standing

  • The marking is placed 145cm above the floor
  • The colour of the marking is white

Assistance dogs

  • Guide dog, Service dog, Signal dog is/are allowed in the space

Walking area

  • A walking area is hardened, even
  • The walking area is 300cm wide
  • Space where it is possible to turn around is available
  • A walking area is hardened, even
  • The walking area is 300cm wide

Seat

  • The seating height of the seat is 46cm
  • There is backrest available on the seat
  • Armrest is available on the seat

Table

  • The height of the free space under the table is 41cm
  • The height of the table top is 45cm from the floor
  • The free legroom under the table is 45cm deep
  • The free legroom under the table is 45cm wide

Counter with fixed height

  • The height of the counter is 116cm
  • The length of the counter is 500cm
  • The depth of the legroom is 0cm
  • Well lit reception is available
  • The lightness contrast of the counter is 0,05NCS against the background

Reception

  • Hearing aid equipment is not available in the room or area
  • Special aids or equipment are not available
  • Staff that have knowledge regarding existing aids and equipment, and how they are used, is available
  • Video phone is not available
  • Access to assistance is available

Card reader with adjustable height

  • There is available a tactile point on the five on the keypad
  • The brightness contrast of the keypad is 0,45NCS
  • The lowest height of the card reader is 0cm
  • The highest height of the card reader is 200cm
  • Possibility to pay with cash available

Booking

  • Adapted homepage according to WAI not available
  • Booking confirmation available via e-mail
  • E-bill not available

Toilet for disabled

  • The type of toilet is one toilet in the space

Sign near door

  • The sign lighting is non-blinding
  • The lower edge of the sign is placed 160cm from the ground
  • The upper edge of the sign is placed 170cm from the ground
  • Sign are available placed on door
  • Sign is not available placed next to door on the same side as the doorhandle
  • The brightness contrast of the sign is 0,30NCS against the background
  • Sign is not available in relief
  • The lower edge of the sign is placed 148cm from the ground
  • The upper edge of the sign is placed 162cm from the ground
  • Sign are available placed on door
  • Sign is not available placed next to door on the same side as the doorhandle

Design of the toilet for disabled

  • The width is 190cm
  • The length is 240cm
  • The free space on left side of toilet as seen from the front is 95cm wide
  • The free space on right side of toilet as seen from the front is 110cm wide
  • The seating height of the toilet is 47cm
  • Seat made of a hard material is available
  • The toilet has a lightness contrast of 0NCS against the background
  • A container with lid is available that is large enough for stoma bags or adult nappies
  • Container with lid is not available
  • The lower edge of the mirror is 104cm from the floor
  • The upper edge of the mirror is 180cm from the floor
  • The hook has a height of 150cm
  • The soap is perfumed
  • The height of the changing table is 97cm
  • The length of the changing table is 64cm
  • The changing table is 64cm wide
  • A means for drying your hands is available 130cm from the floor
  • Drying is placed 27cm from corner
  • Drying is done with paper towel holder
  • Visual evacuation alarm available

Armrest on right hand side as seen from the front

  • The armrest is foldable
  • The height of the grab bar is 79cm

Armrest on left hand side as seen from the front

  • The armrest is foldable
  • The height of the grab bar is 79cm

Armrests

  • The distance between the grab bars is 60cm

Washbasin

  • The upper edge of the basin is 81cm from the floor
  • The centre of the drain pipe is placed 55cm from the side wall
  • Water seal and pipe drawn inside the wall, or to the side, are available
  • The basin has a lightness cotrast of 0NCS against its background
  • The basin has one handle mixer with lever

Emergency alarm

  • Emergency alarm using a light signal outside door is available
  • Emergency alarm using a sound signal outside the door is not available
  • Emergency alarm which goes to a constantly manned reception, or similar, during opening hours is available
  • Staff who have instructions for action in case of emergency are available
  • Door that can be unlocked from the outside without a special tool or key in case of emergency is available

Emergency alarm on electric cord

  • Emergency alarm with switch on a cord is not available

Emergency alarm on wall

  • Higher emergency alarm on the wall is placed 93cm from the floor
  • Higher emergency alarm on the wall is placed 20cm from the floor

Other toilet

  • The type of toilet is one toilet in the space

Design of door sign

  • The brightness contrast of the sign is 0,80NCS against the background
  • The sign has neither relief nor braille
  • The size of capitals is 25mm

Swing door

  • The turning space outside the door is 280cm wide
  • The length of the turning space outside the door is 841cm
  • The free width of the door opening is 74cm
  • The door surface has a lightness contrast of 0NCS against the door frame
  • The door frame has a lightness contrast of 0,10NCS against the surrounding wall
  • The door lock is lock requiring several hand movements

Swing door opens manually

  • The door handle is placed 300cm from the nearest obstacle
  • Door closer is not available on the door

Design of Toilet

  • Shelf for unloading is not available
  • A container with lid is available that is large enough for stoma bags or adult nappies
  • Container with lid is not available
  • The basin has one handle mixer with lever
  • The soap is perfumed
  • Air freshener or similar which gives off scent is not available
  • Visual evacuation alarm not available
  • Cleaning list is not available
  • The frequency of cleaning is 7 times per week

Section heading

Print

Swing door

  • The free width of the door opening is 86cm
  • The door surface has a lightness contrast of 0NCS against the door frame
  • The door frame has a lightness contrast of 0,15NCS against the surrounding wall
  • The door frame has a lightness contrast of 0,15NCS against the surrounding wall

Wide marking with several colours on glass pane

  • The lower edge of the marking is placed 94cm above the ground
  • The upper edge of the marking i placed 113cm above the ground
  • The colour of the marking is brown
  • The other colour of the marking is white
  • The lightness contrast between the colours of the marking is 0,40NCS
  • The height of the threshold is 3cm
  • The height difference to the bevelling is 1cm

Swing door opens manually

  • The door handle is placed 100cm from the nearest obstacle
  • Door closer is available on the door

Indoor environment

  • The sound environment is noise free
  • The sound has a short lingering note
  • The lighting is non-blinding
  • The lighting is even
  • Cleaning products are not perfumed
  • The room is cleaned 7 per week
  • Wall-to-wall textile carpet are not available
  • The evacuation alarm is audible

Assistance dogs

  • Guide dog, Service dog, Signal dog is/are allowed in the space

Walking area

  • A walking area is hardened, even
  • The walking area is 136cm wide
  • Space where it is possible to turn around is available
  • A walking area is hardened, even
  • The walking area is 200cm wide

Stairs

  • There is 10st steps to the resting level
  • The stairs are curved
  • The stairs are 130cm wide
  • The bottom step has a contrast marking of 0NCS
  • The stair steps are 16cm high
  • The top step has a contrast marking of 0NCS
  • Depth of staircase steps is 27cm
  • The staircase is hardened, even
  • There are not available protruding level steps

Handrail on right hand side as seen from below

  • There not available a marking lower part at the end of handrail
  • The handrail extends 27cm past the part
  • There available a handrail that ends abruptly at the upper part
  • There not available a marker at the end of the handrail at the top
  • The brightness contrast of the handrail is 0,40NCS against the background
  • There not available a handrail which runs continuously

Handrail on left hand side as seen from below

  • The height of the handrail is 95cm
  • The handrail extends 20cm past the part
  • There available a handrail that ends abruptly at the lower part
  • There not available a marking lower part at the end of handrail
  • The handrail extends 15cm past the part
  • There available a handrail that ends abruptly at the upper part
  • There not available a marker at the end of the handrail at the top
  • There not available a handrail which runs continuously

Lift

  • The call button is placed 90cm above the ground
  • The distance to the nearest object is 11cm
  • The lightness contrast of the function is 0,50NCS against the background
  • The function is press button
  • The length of the free space is 230cm
  • The width of the free space is 340cm
  • The door surface has a lightness contrast of 0NCS against the door frame
  • The door frame has a lightness contrast of 0,20NCS against the surrounding wall
  • The lift car is 140cm deep
  • The lift car is 103cm wide
  • The difference in level between the lift floor and the area outside is 0mm when the lift has stopped
  • Handrail is not available on the same side as the control panel
  • The handrail has a lightness contrast of 0NCS
  • The handrail is 90cm above the floor
  • Lift that opens out onto a descending staircase is not available

Sliding door

  • The free width of the door opening is 89cm

The door opens automatically

  • Security sensor is available for when the door closes
  • The passage time is 12s

Control panel in lift

  • The lift buttons are 3cm large
  • The type of lift buttons is touch button
  • The lift buttons have neither relief nor braille as a tactile marking
  • Lift button not available which needs to be held in for the duration of the ride
  • Emergency alarm that is placed on or next to the control panel are available
  • Visually marked button for emergency alarm is available
  • Tactile marking on button for emergency alarm is available
  • Alarm instructions in easy to understand Swedish are not available
  • Alarm instructions in braille are not available
  • Alarm instructions as picture symbols are not available
  • A visual confirmation that the alarm has gone through is not available
  • An acoustic confirmation that the alarm has gone through is available
  • Emergency instructions in english are not available

Control panel in the lift

  • The upper row of buttons is placed 106cm from the floor
  • The lower row of buttons is placed 92cm from the floor
  • The distance between the manoeuvering panel and the corner by the door is 74cm
  • The manoeuvering panel is even against wall from the wall
  • The lift button is even against wall

Section heading

Print

Swing door

  • The turning space outside the door is 200cm wide
  • The length of the turning space outside the door is 300cm
  • The free width of the door opening is 87cm
  • The door surface has a lightness contrast of 0NCS against the door frame
  • The door frame has a lightness contrast of 0,05NCS against the surrounding wall
  • The door lock is one hold lock
  • The height of the threshold is 2cm
  • The height difference to the bevelling is 0cm

Swing door opens manually

  • The door handle is placed 135cm from the nearest obstacle
  • Door closer is available on the door

Extra equipped guest room

  • The switch is placed 105cm from the floor
  • The distance to the nearest obstacle is 23cm
  • Light switch that is reachable using a wheelchair or walking frame is available
  • The width is 198cm
  • The length is 198cm
  • The socket is placed 97cm from the floor
  • The distance to the nearest obstacle is 23cm
  • Socket that can be reached using a wheelchair or walking frame is available
  • Access to person lift on-site is not available
  • Mobile person lift that can be borrowed on request is not available
  • The seating height of the seat is 45cm
  • There is backrest available on the seat
  • Armrest is not available on the seat
  • The evacuation alarm is audible
  • The sound environment is noisy
  • The sound has a short lingering note
  • The lighting is non-blinding
  • The lighting is even
  • Occurring daylight is blinding
  • Means for screening off glaring daylight are available
  • It is not allowed to have furred animals in the room
  • Smoking in the room is not allowed
  • Wall-to-wall textile carpet are not available
  • The room is cleaned 7 per week
  • Nickel can be found in nothing
  • Help to carry luggage is not available

Mirror

  • The lower edge of the mirror is 100cm from the floor
  • The upper edge of the mirror is 180cm from the floor

Ordinary bed

  • The bed is 51cm high
  • Bed with slatted base are not available
  • Washable overlay matress are available

Emergency alarm

  • Emergency alarm using a light signal outside door is available
  • Emergency alarm using a sound signal outside the door is not available
  • Staff who have instructions for action in case of emergency are available
  • Emergency alarm or emergency telephone, that is connected to staff around-the-clock, is not available
  • Emergency alarm using a light signal outside door is available
  • Emergency alarm using a sound signal outside the door is not available
  • Emergency alarm which goes to a constantly manned reception, or similar, during opening hours is available
  • Staff who have instructions for action in case of emergency are available
  • Door that can be unlocked from the outside without a special tool or key in case of emergency is available
  • Emergency alarm using a light signal outside door is available
  • Emergency alarm using a sound signal outside the door is not available
  • Emergency alarm which goes to a constantly manned reception, or similar, during opening hours is available
  • Staff who have instructions for action in case of emergency are available

Hook

  • The hook has a height of 160cm
  • The hook is placed 40cm from corner

Design of the toilet for disabled

  • The width is 150cm
  • The length is 150cm
  • The free space on left side of toilet as seen from the front is 90cm wide
  • The free space on right side of toilet as seen from the front is 10cm wide
  • The seating height of the toilet is 44cm
  • Seat made of a hard material is not available
  • The toilet has a lightness contrast of 0NCS against the background
  • A container with lid is not available that is large enough for stoma bags or adult nappies
  • Container with lid is available
  • The lower edge of the mirror is 101cm from the floor
  • The upper edge of the mirror is 180cm from the floor
  • The hook has a height of 140cm
  • The soap is perfumed
  • A means for drying your hands is available 120cm from the floor
  • Drying is placed 51cm from corner
  • Drying is done with loose cloth towels
  • Visual evacuation alarm not available

Armrest on right hand side as seen from the front

  • The armrest is foldable
  • The height of the grab bar is 81cm

Armrest on left hand side as seen from the front

  • The armrest is foldable
  • The height of the grab bar is 81cm

Armrests

  • The distance between the grab bars is 52cm

Washbasin

  • The upper edge of the basin is 81cm from the floor
  • The centre of the drain pipe is placed 43cm from the side wall
  • Water seal and pipe drawn inside the wall, or to the side, are available
  • The basin has a lightness cotrast of 0NCS against its background
  • The basin has one handle mixer with lever

Emergency alarm on electric cord

  • Emergency alarm with switch on a cord is available
  • Emergency alarm with switch on a cord is available

Emergency alarm on wall

  • Higher emergency alarm on the wall is placed 95cm from the floor
  • Higher emergency alarm on the wall is placed 22cm from the floor
  • Higher emergency alarm on the wall is placed 98cm from the floor
  • Higher emergency alarm on the wall is placed 22cm from the floor

Shower

  • The length of the free space is 150cm
  • The width of the free space is 150cm
  • The shower mixer is one handle mixer with something other than a lever
  • The mixer tap is placed 108cm above the floor
  • The mixer tap is placed 43cm from the nearest corner
  • Shower that can be used as a hand shower is available
  • The soap is perfumed

Section heading

Print

Serving of food and drink

  • The height of the free space under the table is 65cm
  • The height of the table top is 75,5cm from the floor
  • The free legroom under the table is 90cm deep
  • The free legroom under the table is 180cm wide
  • The seating height of the seat is 45cm
  • There is backrest available on the seat
  • Armrest is not available on the seat
  • Dishes that can be put together according to the guest’s wishes in cases of allergy are available
  • Possibility to pre-order custom made food is available
  • Available types of food: gluten free, lactose free, fat free, whitout pork, vegetarian
  • The food is handled with different structure of raw materials, with separate heating of raw materials
  • The walking area is 100cm wide

Menu

  • The character size on the menu is 50mm
  • The text has a brightness contrast of 0,85NCS against background
  • The menu has simple font
  • Access to list of contents is not available

Mobile bell

  • The lightness contrast of the bell is 0,75NCS against the background

Manned check-out

  • The passage by the check-out is 180cm wide
  • The check-out price is placed 110cm from the ground
  • The lightness contrast of price registered is 0,85NCS
  • Character size of registered price is 2mm
  • The height of the check-out is 90cm from the ground

Card reader fixed in place

  • The distance from the floor to the uppermost button or the card reader’s highest point is 87cm
  • There is available a tactile point on the five on the keypad
  • The brightness contrast of the keypad is 085NCS

Check-out

  • Personal service is available on request

Height of serving counters and tables

  • The buffet table is 90cm high
  • The height of the self service counter is 82cm

Section heading

Print

Indoor environment

  • The sound environment is noise free
  • The sound has a short lingering note
  • The lighting is non-blinding
  • The lighting is even
  • Cleaning products are not perfumed
  • The room is cleaned 7 per week
  • Wall-to-wall textile carpet are not available
  • The evacuation alarm is audible

Assistance dogs

  • Guide dog, Service dog, Signal dog is/are allowed in the space

Walking area

  • A walking area is hardened, even
  • Space where it is possible to turn around is available
  • A walking area is hardened, even
  • The walking area is 130cm wide

Stairs

  • There is 10st steps to the resting level
  • The stairs are curved
  • The stairs are 130cm wide
  • The bottom step has a contrast marking of 0NCS
  • The stair steps are 16cm high
  • The top step has a contrast marking of 0NCS
  • Depth of staircase steps is 27cm
  • The staircase is hardened, even
  • There are not available protruding level steps

Handrail on right hand side as seen from below

  • The height of the handrail is 96cm
  • There not available a marking lower part at the end of handrail
  • The handrail extends 27cm past the part
  • There available a handrail that ends abruptly at the upper part
  • There not available a marker at the end of the handrail at the top
  • The brightness contrast of the handrail is 0,40NCS against the background
  • There not available a handrail which runs continuously

Handrail on left hand side as seen from below

  • The height of the handrail is 95cm
  • The handrail extends 20cm past the part
  • There available a handrail that ends abruptly at the lower part
  • There not available a marking lower part at the end of handrail
  • The handrail extends 15cm past the part
  • There available a handrail that ends abruptly at the upper part
  • There not available a marker at the end of the handrail at the top
  • There not available a handrail which runs continuously

Lift

  • The call button is placed 90cm above the ground
  • The distance to the nearest object is 11cm
  • The lightness contrast of the function is 0,50NCS against the background
  • The function is press button
  • The length of the free space is 230cm
  • The width of the free space is 340cm
  • The door surface has a lightness contrast of 0NCS against the door frame
  • The door frame has a lightness contrast of 0,20NCS against the surrounding wall
  • The lift car is 140cm deep
  • The lift car is 103cm wide
  • The difference in level between the lift floor and the area outside is 0mm when the lift has stopped
  • Handrail is not available on the same side as the control panel
  • The handrail has a lightness contrast of 0NCS
  • The handrail is 90cm above the floor
  • Lift that opens out onto a descending staircase is not available

Sliding door

  • The free width of the door opening is 89cm

The door opens automatically

  • Security sensor is available for when the door closes
  • The passage time is 12s

Control panel in lift

  • The lift buttons are 3cm large
  • The type of lift buttons is touch button
  • The lift buttons have neither relief nor braille as a tactile marking
  • Lift button not available which needs to be held in for the duration of the ride
  • Emergency alarm that is placed on or next to the control panel are available
  • Visually marked button for emergency alarm is available
  • Tactile marking on button for emergency alarm is available
  • Alarm instructions in easy to understand Swedish are not available
  • Alarm instructions in braille are not available
  • Alarm instructions as picture symbols are not available
  • A visual confirmation that the alarm has gone through is not available
  • An acoustic confirmation that the alarm has gone through is available
  • Emergency instructions in english are not available

Control panel in the lift

  • The upper row of buttons is placed 106cm from the floor
  • The lower row of buttons is placed 92cm from the floor
  • The distance between the manoeuvering panel and the corner by the door is 74cm
  • The manoeuvering panel is even against wall from the wall
  • The lift button is even against wall

Section heading

Print

Swing door

  • The free width of the door opening is 85cm
  • The door surface has a lightness contrast of 0NCS against the door frame
  • The door frame has a lightness contrast of 0,05NCS against the surrounding wall
  • The door frame has a lightness contrast of 0,05NCS against the surrounding wall
  • The turning space outside the door is 280cm wide
  • The length of the turning space outside the door is 841cm
  • The free width of the door opening is 74cm
  • The door surface has a lightness contrast of 0NCS against the door frame
  • The door frame has a lightness contrast of 0,10NCS against the surrounding wall
  • The door lock is lock requiring several hand movements

Swing door opens manually

  • The door handle is placed 95cm from the nearest obstacle
  • Door closer is not available on the door
  • The door handle is placed 300cm from the nearest obstacle
  • Door closer is not available on the door

Indoor environment

  • The sound environment is noise free
  • The sound has a short lingering note
  • The lighting is non-blinding
  • The lighting is even
  • Occurring daylight is blinding
  • Means for screening off glaring daylight are available
  • Cleaning products are not perfumed
  • The room is cleaned 7 per week
  • Wall-to-wall textile carpet are not available
  • The evacuation alarm is audible

Assistance dogs

  • Guide dog, Service dog, Signal dog is/are allowed in the space

Walking area

  • A walking area is hardened, even
  • Space where it is possible to turn around is available
  • A walking area is hardened, even
  • The walking area is 300cm wide

Seat

  • The seating height of the seat is 45cm
  • There is backrest available on the seat
  • Armrest is not available on the seat

Table

  • The height of the free space under the table is 65cm
  • The height of the table top is 75,5cm from the floor
  • The free legroom under the table is 90cm deep
  • The free legroom under the table is 180cm wide
  • Hearing aid equipment is not available in the room or area

Toilet for disabled

  • The type of toilet is one toilet in the space

Sign near door

  • The sign lighting is non-blinding
  • The lower edge of the sign is placed 160cm from the ground
  • The upper edge of the sign is placed 170cm from the ground
  • Sign are available placed on door
  • Sign is not available placed next to door on the same side as the doorhandle
  • The brightness contrast of the sign is 0,30NCS against the background
  • Sign is not available in relief
  • The lower edge of the sign is placed 148cm from the ground
  • The upper edge of the sign is placed 162cm from the ground
  • Sign are available placed on door
  • Sign is not available placed next to door on the same side as the doorhandle

Design of the toilet for disabled

  • The width is 190cm
  • The length is 240cm
  • The free space on left side of toilet as seen from the front is 95cm wide
  • The free space on right side of toilet as seen from the front is 110cm wide
  • The seating height of the toilet is 47cm
  • Seat made of a hard material is available
  • The toilet has a lightness contrast of 0NCS against the background
  • A container with lid is available that is large enough for stoma bags or adult nappies
  • Container with lid is not available
  • The lower edge of the mirror is 104cm from the floor
  • The upper edge of the mirror is 180cm from the floor
  • The hook has a height of 150cm
  • The soap is perfumed
  • The height of the changing table is 97cm
  • The length of the changing table is 64cm
  • The changing table is 64cm wide
  • A means for drying your hands is available 130cm from the floor
  • Drying is placed 27cm from corner
  • Drying is done with paper towel holder
  • Visual evacuation alarm available

Armrest on right hand side as seen from the front

  • The armrest is foldable
  • The height of the grab bar is 79cm

Armrest on left hand side as seen from the front

  • The armrest is foldable
  • The height of the grab bar is 79cm

Armrests

  • The distance between the grab bars is 60cm

Washbasin

  • The upper edge of the basin is 81cm from the floor
  • The centre of the drain pipe is placed 55cm from the side wall
  • Water seal and pipe drawn inside the wall, or to the side, are available
  • The basin has a lightness cotrast of 0NCS against its background
  • The basin has one handle mixer with lever

Emergency alarm

  • Emergency alarm using a light signal outside door is available
  • Emergency alarm using a sound signal outside the door is not available
  • Emergency alarm which goes to a constantly manned reception, or similar, during opening hours is available
  • Staff who have instructions for action in case of emergency are available
  • Door that can be unlocked from the outside without a special tool or key in case of emergency is available

Emergency alarm on electric cord

  • Emergency alarm with switch on a cord is not available

Emergency alarm on wall

  • Higher emergency alarm on the wall is placed 93cm from the floor
  • Higher emergency alarm on the wall is placed 20cm from the floor

Other toilet

  • The type of toilet is one toilet in the space

Design of door sign

  • The brightness contrast of the sign is 0,80NCS against the background
  • The sign has neither relief nor braille
  • The size of capitals is 25mm

Design of Toilet

  • Shelf for unloading is not available
  • A container with lid is available that is large enough for stoma bags or adult nappies
  • Container with lid is not available
  • The basin has one handle mixer with lever
  • The soap is perfumed
  • Air freshener or similar which gives off scent is not available
  • Visual evacuation alarm not available
  • Cleaning list is not available
  • The frequency of cleaning is 7 times per week

Parking and footpath

Skriv ut

Footpath

Footpath

The gateway

Entrance

Skriv ut

Swing door

Single colour marking on the glass surface at eye level for sitting

Single colour marking on the glass surface at eye level when standing

Wiping grid inside door

Swing door opens manually

Entrance

Sign on wall

Swing door in inner entrance

Swing door in inner entrance

Single colour marking on the glass surface at eye level for sitting

Single colour marking on the glass surface at eye level when standing

Threshold

Swing door in inner entrance opens manually

Lobby

Skriv ut

Indoor environment

Single colour marking on the glass surface at eye level for sitting

Single colour marking on the glass surface at eye level when standing

Assistance dogs

Walking area

Walking area

Seat

Table

Counter with fixed height

Reception

Card reader with adjustable height

Booking

Toilet for disabled

Sign near door

Design of the toilet for disabled

Design of the toilet for disabled

Design of the toilet for disabled

Armrest on right hand side as seen from the front

Armrest on left hand side as seen from the front

Armrests

Washbasin

Emergency alarm

Emergency alarm on electric cord

Emergency alarm on wall

Emergency alarm on wall

Other toilet

Sign near door

Design of door sign

Swing door

Swing door opens manually

Design of Toilet

Passage from lobby to guest rooms

Skriv ut

Swing door

Wide marking with several colours on glass pane

Swing door opens manually

Indoor environment

Assistance dogs

Walking area

Walking area

Stairs

Handrail on right hand side as seen from below

Handrail on left hand side as seen from below

Lift

Lift

Lift

Sliding door

The door opens automatically

Control panel in lift

Control panel in the lift

Guest room

Skriv ut

Swing door

Swing door opens manually

Extra equipped guest room

Extra equipped guest room

Extra equipped guest room

Mirror

Ordinary bed

Emergency alarm

Hook

Design of the toilet for disabled

Design of the toilet for disabled

Armrest on right hand side as seen from the front

Armrest on left hand side as seen from the front

Armrests

Washbasin

Emergency alarm

Emergency alarm on electric cord

Emergency alarm on wall

Emergency alarm on wall

Shower

Shower

Emergency alarm

Emergency alarm on electric cord

Emergency alarm on wall

Emergency alarm on wall

Restaurant

Skriv ut

Serving of food and drink

Serving of food and drink

Serving of food and drink

Menu

Mobile bell

Manned check-out

Card reader fixed in place

Check-out

Height of serving counters and tables

Height of serving counters and tables

Passage från lobby till konferensrum

Skriv ut

Indoor environment

Assistance dogs

Walking area

Walking area

Stairs

Handrail on right hand side as seen from below

Handrail on left hand side as seen from below

Lift

Lift

Lift

Sliding door

The door opens automatically

Control panel in lift

Control panel in the lift

Conference room

Skriv ut

Swing door

Swing door opens manually

Indoor environment

Assistance dogs

Walking area

Walking area

Seat

Table

Toilet for disabled

Sign near door

Design of the toilet for disabled

Design of the toilet for disabled

Design of the toilet for disabled

Armrest on right hand side as seen from the front

Armrest on left hand side as seen from the front

Armrests

Washbasin

Emergency alarm

Emergency alarm on electric cord

Emergency alarm on wall

Emergency alarm on wall

Other toilet

Sign near door

Design of door sign

Swing door

Swing door opens manually

Design of Toilet