Denna webbplats använder teknik som troligen inte stöds i din webbläsare, därför kan vissa saker se konstiga ut eller inte fungera. Vi rekommenderar att du byter till en modern webbläsare istället.
Skip to main content

Braås bibliotek

Hoppa över karta

Contact

Uppdated
Address
Betlehemsvägen 1
360 42
Braås
Telephone
+46 474-62 20 40
Views

Filter on your needs

Description of the site you are visiting

Skriv ut hela anläggningen

Section heading

Print

Freestanding or lined up parking space for disabled

  • The disabled parking space is marked by sign with symbol, ground symbol, square marking
  • The disabled parking space is 3m wide
  • The lengthways tilt of the disabled parking space is 0.4%
  • The disbaled parking space tilts 0.2% sideways
  • The disabled parking space is 24m from the entrance
  • Lighting not available
  • Tactile trail is not available

Footpath

  • The pedestrian path is 0,94m wide
  • The surface of the pedestrian path is hardened, even
  • The walking area tilts 0.3% sideways
  • Lighting is not available
  • The hard and smooth walking surface is 3m wide

Section heading

Print

Alternative slope

  • The lengthways tilt is 3,1%
  • The length of the slope is 7m

Sign from ceiling

  • When signs are placed high up is available an additional sign that it is easy to get next to

Sign on wall

  • The lower edge of the sign is placed 189cm from the ground
  • The upper edge of the sign is placed 216cm from the ground

Swing door

  • The turning space outside the door is 300cm wide
  • The length of the turning space outside the door is 300cm
  • The turning space outside the door tilts 0.2% sideways
  • The turning space outside the door tilts 0.3% lengthways
  • The free width of the door opening is 93cm
  • Lighting is available
  • The door surface has a lightness contrast of 0NCS against the door frame
  • The door frame has a lightness contrast of 0.44NCS against the surrounding wall
  • The turning space inside the door is 300cm wide
  • The length of the turning space inside the door is 300cm
  • The turning space inside the door tilts 0.1% sideways
  • The turning space inside the door tilts 0.05% lengthways

Threshold

  • The height of the threshold is 3cm

Doormat inside door

  • The doormat is thin, loose

Swing door opens with switch for door opener

  • The switch for the door opener outside the door is placed 108cm above the floor
  • The switch for the door opener outside the door is placed 300cm from the nearest obstacle
  • The switch for the door opener outside the door has a lightness contrast of 0.13NCS
  • The switch for the door opener inside the door is placed 101cm above the floor
  • The switch for the door opener inside the door is placed 66cm from the nearest obstacle
  • The switch for the door opener inside the door has a lightness contrast of 0.61NCS

Area where door opens up

  • Door which opens out into area where people pass is not available
  • Marking of the area covered by the door as it opens up, is not available that can be felt with a white cane
  • Security sensor is not available for when the door opens
  • Security sensor is not available for when the door closes
  • The passage time is 12s
  • Door which opens out into area where people pass is available
  • Marking of the area covered by the door as it opens up, is not available that can be felt with a white cane
  • Security sensor is not available for when the door opens
  • Security sensor is not available for when the door closes
  • The passage time is 12s

Swing door in inner entrance

  • The turning space outside the door is 300cm wide
  • The length of the turning space outside the door is 300cm
  • The turning space outside the door tilts 0.1% sideways
  • The turning space outside the door tilts 0.3% lengthways
  • The free width of the door opening is 93cm
  • Lighting is not available
  • The door surface has a lightness contrast of 0NCS against the door frame
  • The door frame has a lightness contrast of 0.26NCS against the surrounding wall
  • The turning space inside the door is 300cm wide
  • The length of the turning space inside the door is 300cm
  • The turning space inside the door tilts 0.1% sideways
  • The turning space inside the door tilts 0.3% lengthways

Swing door in inner entrance opens with switch for door opener

  • The switch for the door opener outside the door is placed 101cm above the floor
  • The switch for the door opener outside the door is placed 66cm from the nearest obstacle
  • The switch for the door opener outside the door has a lightness contrast of 0,61NCS
  • The switch for the door opener inside the door is placed 101cm above the floor
  • The switch for the door opener inside the door is placed 65cm from the nearest obstacle
  • The switch for the door opener inside the door has a lightness contrast of 0.61NCS

Section heading

Print

Toilet for disabled

  • The type of toilet is one toilet in the space

Swing door

  • The turning space outside the door is 300cm wide
  • The length of the turning space outside the door is 300cm
  • The free width of the door opening is 86cm
  • The door surface has a lightness contrast of 0.34NCS against the door frame
  • The door frame has a lightness contrast of 0.06NCS against the surrounding wall
  • The door lock is one hold lock
  • The turning space outside the door is 300cm wide
  • The length of the turning space outside the door is 300cm
  • The free width of the door opening is 66cm
  • The door surface has a lightness contrast of 0.35NCS against the door frame
  • The door frame has a lightness contrast of 0.1NCS against the surrounding wall
  • The door lock is one hold lock
  • Door closer is not available on the door
  • Shelf for unloading is not available
  • Changing table is not available
  • A container with lid is not available that is large enough for stoma bags or adult nappies
  • The basin has two taps
  • Air freshener or similar which gives off scent is not available
  • Visual evacuation alarm not available
  • Cleaning list is available
  • The frequency of cleaning is 5 times per week

Swing door opens manually

  • The door handle is placed 72cm from the nearest obstacle
  • Door closer is not available on the door

Design of the toilet for disabled

  • The width is 170cm
  • The length is 169cm
  • The free space on left side of toilet as seen from the front is 77cm wide
  • The free space on right side of toilet as seen from the front is 37cm wide
  • The seating height of the toilet is 45cm
  • Seat made of a hard material is available
  • The toilet has a lightness contrast of 0.04NCS against the background
  • Shelf for unloading is not available
  • A container with lid is not available that is large enough for stoma bags or adult nappies
  • The lower edge of the mirror is 123cm from the floor
  • The upper edge of the mirror is 164cm from the floor
  • The hook has a height of 127cm
  • The hook is placed 53cm from corner
  • Changing table is not available
  • Air freshener or similar which gives off scent is not available
  • A means for drying your hands is available 112cm from the floor
  • Drying is placed 80cm from corner
  • Drying is done with paper towel holder
  • Visual evacuation alarm not available
  • Cleaning list is available
  • The frequency of cleaning is 5 times per week

Armrest on right hand side as seen from the front

  • The armrest is foldable
  • The height of the grab bar is 80cm

Armrest on left hand side as seen from the front

  • The armrest is foldable
  • The height of the grab bar is 80cm

Armrests

  • The distance between the grab bars is 57cm

Washbasin

  • The upper edge of the basin is 89cm from the floor
  • The centre of the drain pipe is placed 39cm from the side wall
  • Water seal and pipe drawn inside the wall, or to the side, are not available
  • The basin has a lightness cotrast of 0.04NCS against its background
  • The basin has one handle mixer with lever

Emergency alarm

  • Emergency alarm using a light signal outside door is available
  • Emergency alarm using a sound signal outside the door is available
  • Emergency alarm which goes to a constantly manned reception, or similar, during opening hours is not available
  • Staff who have instructions for action in case of emergency are not available
  • Door that can be unlocked from the outside without a special tool or key in case of emergency is available

Emergency alarm on wall

  • Lower emergency alarm on the wall is placed 23cm from the floor
  • Higher emergency alarm on the wall is placed 127cm from the floor

Other toilet

  • The type of toilet is several toilets in the space

Section heading

Print

Hook

  • The hook has a height of 100cm
  • The hook is placed 126cm from corner

Section heading

Print

Swing door

  • The free width of the door opening is 80cm
  • The door surface has a lightness contrast of 0NCS against the door frame
  • The door frame has a lightness contrast of 0.74NCS against the surrounding wall

Large, single colour marking on glass pane

  • The lower edge of the marking is placed 100cm above the ground
  • The upper edge of the marking i placed 112cm above the ground
  • The colour of the marking is brown

Threshold

  • The height of the threshold is 0.5cm
  • The height difference to the bevelling is 0.1cm

Swing door opens with switch for door opener

  • The switch for the door opener outside the door is placed 99cm above the floor
  • The switch for the door opener outside the door is placed 300cm from the nearest obstacle
  • The switch for the door opener outside the door has a lightness contrast of 0.11NCS
  • The switch for the door opener inside the door is placed 100cm above the floor
  • The switch for the door opener inside the door is placed 16cm from the nearest obstacle
  • The switch for the door opener inside the door has a lightness contrast of 0.52NCS

Area where door opens up

  • Door which opens out into area where people pass is not available
  • Marking of the area covered by the door as it opens up, is not available that can be felt with a white cane
  • Security sensor is available for when the door opens
  • Security sensor is not available for when the door closes
  • The passage time is 20s

Indoor environment

  • The sound environment is noise free
  • The sound has a short lingering note
  • The lighting is blinding
  • The lighting is even
  • Means for screening off glaring daylight are available
  • Cleaning products are not perfumed
  • The room is cleaned 5 per week
  • Wall-to-wall textile carpet are not available
  • The evacuation alarm is audible, visual
  • The sound environment is noise free
  • The sound has a short lingering note
  • The lighting is blinding
  • The lighting is uneven
  • Means for screening off glaring daylight are available
  • Cleaning products are not perfumed
  • The room is cleaned 5 per week
  • Wall-to-wall textile carpet are not available
  • The evacuation alarm is missing

Assistance dogs

  • No assistance dog is/are allowed in the space
  • No assistance dog is/are allowed in the space

Walking area

  • A walking area is hardened, even
  • The walking area is 93cm wide
  • Space where it is possible to turn around is available
  • The walking area is 300cm wide
  • A walking area is hardened, even
  • The walking area is 56cm wide
  • Space where it is possible to turn around is available
  • The walking area is 300cm wide
  • Some parts have a limited walking area that is 146cm wide

Seat

  • The seating height of the seat is 38cm
  • There is backrest available on the seat
  • Armrest is not available on the seat

Table

  • The height of the free space under the table is 70cm
  • The height of the table top is 73cm from the floor
  • The free legroom under the table is 73cm deep
  • The free legroom under the table is 67cm wide

Counter with adjustable height

  • The length of the counter is 300cm
  • The depth of the legroom is 0cm
  • Well lit reception is available
  • The lowest height of the reception counter is 70cm
  • The highest height of the counter is 108cm
  • The lightness contrast of the counter is 0NCS against the background
  • Special aids or equipment are not available
  • Staff that have knowledge regarding existing aids and equipment, and how they are used, is not available
  • Video phone is not available
  • Access to assistance is not available
  • Adapted homepage according to WAI available
  • Booking confirmation available via e-mail
  • E-bill available
  • Access to personal service is available
  • The lowest shelf is placed 150cm from the ground
  • The highest shelf is placed 180cm from the ground
  • A magnifying glass with a built-in lamp is not available

Other computer tables

  • The height of the free space under the table is 70cm
  • The height of the table top is 74cm from the floor
  • The free legroom under the table is 44cm deep
  • The free legroom under the table is 104cm wide
  • All information is available in audio format
  • Some information is available in easy to read Swedish
  • None information is available in braille
  • All information available on the web in adapted form

Gateway

  • The free width of the door opening is 90cm
  • The door frame has a lightness contrast of 0.01NCS against the surrounding wall

Loose object in walking area

  • Loose object in pathway is available

Parking and footpath

Skriv ut

Freestanding or lined up parking space for disabled

Footpath

Entrance

Skriv ut

Alternative slope

Sign from ceiling

Sign on wall

Swing door

Swing door

Threshold

Doormat inside door

Swing door opens with switch for door opener

Swing door opens with switch for door opener

Area where door opens up

Swing door in inner entrance

Swing door in inner entrance

Swing door in inner entrance opens with switch for door opener

Swing door in inner entrance opens with switch for door opener

Area where door opens up

Toilet indoors

Skriv ut

Toilet for disabled

Swing door

Swing door

Swing door opens manually

Design of the toilet for disabled

Armrest on right hand side as seen from the front

Armrest on left hand side as seen from the front

Armrests

Washbasin

Emergency alarm

Emergency alarm on wall

Emergency alarm on wall

Other toilet

Swing door

Hook

Skriv ut

Hook

Library room

Skriv ut

Swing door

Large, single colour marking on glass pane

Threshold

Swing door opens with switch for door opener

Swing door opens with switch for door opener

Area where door opens up

Indoor environment

Assistance dogs

Walking area

Walking area

Seat

Table

Counter with adjustable height

Other computer tables

Gateway

Indoor environment

Assistance dogs

Walking area

Walking area

Loose object in walking area