Denna webbplats använder teknik som troligen inte stöds i din webbläsare, därför kan vissa saker se konstiga ut eller inte fungera. Vi rekommenderar att du byter till en modern webbläsare istället.
Skip to main content

ABF Västerås (Culturen)

Hoppa över karta

Contact

Uppdated
6/29/2018 11:25:43 AM
Address
Sintervägen 6
72130
Västerås
Telephone
+46 021-4707500
Home page
Views

Filter on your needs

Description of the site you are visiting

Skriv ut hela anläggningen

Section heading

Print

Drop-off and pick-up area

  • The area for boarding and alighting is 10m
  • The area for boarding and alighting is 5m from the entrance
  • Lighting is available
  • Tactile trail is not available

Section heading

Print

Freestanding or lined up parking space for disabled

  • The disabled parking space is marked by sign with symbol, square marking
  • The disabled parking space is 6,8m wide
  • The lengthways tilt of the disabled parking space is 1,6%
  • The surface of the disabled parking space is hardened, even
  • The disbaled parking space tilts 0,7% sideways
  • The disabled parking space is 7m from the entrance
  • Lighting available

Section heading

Print

Swing door

  • The turning space outside the door is 300cm wide
  • The length of the turning space outside the door is 300cm
  • The turning space outside the door tilts 0,6% sideways
  • The turning space outside the door tilts 1,9% lengthways
  • The free width of the door opening is 86cm
  • Lighting is available
  • The door surface has a lightness contrast of 0,00NCS against the door frame
  • The door frame has a lightness contrast of 0,35NCS against the surrounding wall
  • The turning space inside the door is 300cm wide
  • The length of the turning space inside the door is 300cm
  • The turning space inside the door tilts 0,0% sideways
  • The turning space inside the door tilts 0,6% lengthways
  • The free width of the door opening is 88cm

Single colour marking on the glass surface at eye level for sitting

  • The marking is placed 107cm above the floor
  • The colour of the marking is blue
  • The marking is placed 90cm above the floor
  • The colour of the marking is white

Marking with several colours on the glass surface at eye level for sitting

  • The marking is placed 107cm above the floor
  • The colour of the marking is blue
  • The other colour of the marking is
  • The lightness contrast between the colours of the marking is 0,00NCS
  • The marking is placed 94 cm above the floor
  • The colour of the marking is white
  • The other colour of the marking is
  • The lightness contrast between the colours of the marking is 0,00NCS

Large, single colour marking on glass pane

  • The lower edge of the marking is placed 103cm above the ground
  • The upper edge of the marking i placed 111cm above the ground
  • The colour of the marking is blue

Wide marking with several colours on glass pane

  • The lower edge of the marking is placed 103cm above the ground
  • The upper edge of the marking i placed 111cm above the ground
  • The colour of the marking is blue
  • The other colour of the marking is
  • The lightness contrast between the colours of the marking is 0,00NCS

Wiping grid outside door

  • The wiping grid is inset level with ground

Threshold

  • The height of the threshold is 2cm
  • The height difference to the bevelling is 1cm

Runner inside door

  • The runner is inset level with ground

Swing door opens only manually

  • The door handle is placed 163cm from the nearest obstacle
  • Door closer is available on the door

Swing door opens with switch for door opener

  • The switch for the door opener outside the door is placed 97cm above the floor
  • The switch for the door opener outside the door is placed 90cm from the nearest obstacle
  • The switch for the door opener outside the door has a lightness contrast of 0,20NCS
  • Door which opens out into area where people pass is not available
  • Marking of the area covered by the door as it opens up, is not available that can be felt with a white cane
  • Security sensor is not available for when the door opens
  • Security sensor is available for when the door closes
  • The passage time is 669s
  • The switch for the door opener inside the door is placed 116cm above the floor
  • The switch for the door opener inside the door is placed 300cm from the nearest obstacle
  • The switch for the door opener inside the door has a lightness contrast of 0,70NCS

Entrance

  • Designated smoking area is available
  • A smoking area is available that is placed so that smoke is avoided inside the building and by the entrance

Seat

  • The seating height of the seat is 46cm
  • There is backrest not available on the seat
  • Armrest is not available on the seat

Swing door in inner entrance

  • The turning space outside the door is 300cm wide
  • The length of the turning space outside the door is 300cm
  • The turning space outside the door tilts 0,1 % sideways
  • The turning space outside the door tilts -0,3 % lengthways
  • The free width of the door opening is 90cm
  • Lighting is available
  • The door surface has a lightness contrast of 0,00NCS against the door frame
  • The door frame has a lightness contrast of 0,10 NCS against the surrounding wall
  • The turning space inside the door is 300cm wide
  • The length of the turning space inside the door is 300cm
  • The turning space inside the door tilts -0,2% sideways
  • The turning space inside the door tilts -0,2% lengthways

Single colour marking on the glass surface at eye level when standing

  • The marking is placed 150 cm above the floor
  • The colour of the marking is white

Markings with several colours on the glass surface at eye level for standing

  • The marking is placed 154cm above the floor
  • The colour of the marking is white
  • The other colour of the marking is
  • The lightness contrast between the colours of the marking is 0,00NCS

Swing door in inner entrance opens manually

  • The door handle is placed 288cm from the nearest obstacle
  • Door closer is available on the door

Swing door in inner entrance opens with switch for door opener

  • The switch for the door opener outside the door is placed 116cm above the floor
  • The switch for the door opener outside the door is placed 300cm from the nearest obstacle
  • The switch for the door opener outside the door has a lightness contrast of 0,70NCS
  • Door which opens out into area where people pass is not available
  • Marking of the area covered by the door as it opens up, is not available that can be felt with a white cane
  • Security sensor is not available for when the door opens
  • Security sensor is available for when the door closes
  • The passage time is 564s
  • The switch for the door opener inside the door is placed 98 cm above the floor
  • The switch for the door opener inside the door is placed 300cm from the nearest obstacle
  • The switch for the door opener inside the door has a lightness contrast of 0,35NCS

Indoor environment

  • The sound environment is noise free
  • The sound has a short lingering note
  • The lighting is non-blinding
  • The lighting is even
  • Wall-to-wall textile carpet are not available
  • The runner is loose
  • The evacuation alarm is audible, visual

Assistance dogs

  • Guide dog, Service dog, Signal dog is/are allowed in the space

Walking area

  • A walking area is hardened, even
  • The walking area is 300cm wide
  • Space where it is possible to turn around is available
  • A walking area is hardened, even
  • The walking area is 300cm wide

Sign on wall

  • The sign lighting is non-blinding
  • The lower edge of the sign is placed 175,5cm from the ground
  • The upper edge of the sign is placed 241cm from the ground
  • The brightness contrast of the sign is 0,85NCS against the background
  • Sign is not available in relief
  • The sign has neither relief nor braille

Stairs

  • The stairs are compensated by lift
  • The unsupported staircase is marked visually at the top, visually at the bottom, tactile marking at the bottom
  • There is 19st steps to the resting level
  • The stairs are straight
  • The stairs are 120cm wide
  • The bottom step has a contrast marking of 0,70NCS
  • The stair steps are 16,6cm high
  • The top step has a contrast marking of 0,70NCS
  • Depth of staircase steps is 30,6cm
  • There are not available protruding level steps
  • The staircase is hardened, even, non-slippery

Handrail on right hand side as seen from below

  • The height of the handrail is 104cm
  • The handrail extends 0cm past the part
  • Handrail stops 0cm before the bottom end
  • There available a handrail that ends abruptly at the lower part
  • There available a marking lower part at the end of handrail
  • The handrail extends 0cm past the part
  • The handrail ends 0cm before the top part
  • There available a handrail that ends abruptly at the upper part
  • There available a marker at the end of the handrail at the top
  • The brightness contrast of the handrail is 0,35NCS against the background
  • There available a handrail which runs continuously

Handrail on left hand side as seen from below

  • The height of the handrail is 104cm
  • The handrail extends 0cm past the part
  • Handrail stops 0cm before the bottom end
  • There available a handrail that ends abruptly at the lower part
  • There available a marking lower part at the end of handrail
  • The handrail extends 0cm past the part
  • The handrail ends 0cm before the top part
  • There available a handrail that ends abruptly at the upper part
  • There available a marker at the end of the handrail at the top
  • The brightness contrast of the handrail is 0,35NCS against the background
  • There available a handrail which runs continuously

Lift

  • The call button is placed 86cm above the ground
  • The distance to the nearest object is 91,5cm
  • The lightness contrast of the function is 0,80NCS against the background
  • The function is press button
  • The length of the free space is 240cm
  • The width of the free space is 197,1cm
  • The lift car is 148,7cm deep
  • The lift car is 100,8cm wide
  • The difference in level between the lift floor and the area outside is 0mm when the lift has stopped
  • Handrail is available on the same side as the control panel
  • The handrail has a lightness contrast of 0,50NCS
  • The handrail is 83cm above the floor
  • The seat is
  • Lift that opens out onto a descending staircase is not available

Door contrast

  • The door surface has a lightness contrast of 0,00NCS against the door frame
  • The door frame has a lightness contrast of 0,00NCS against the surrounding wall

Swing door opens manually

  • The door handle is placed 74,1cm from the nearest obstacle
  • Door closer is available on the door

Swing door opens with switch for door opener

  • The switch for the door opener outside the door is placed 87cm above the floor
  • The switch for the door opener outside the door is placed 106cm from the nearest obstacle
  • The switch for the door opener outside the door has a lightness contrast of 0,50NCS
  • Door which opens out into area where people pass is not available
  • Marking of the area covered by the door as it opens up, is not available that can be felt with a white cane
  • Security sensor is not available for when the door opens
  • Security sensor is not available for when the door closes
  • The passage time is 1160s

Control panel in lift

  • The lift buttons are 5 cm large
  • The type of lift buttons is raised
  • The lift buttons have neither relief nor braille as a tactile marking
  • Lift button available which needs to be held in for the duration of the ride
  • Emergency alarm that is placed on or next to the control panel are available
  • Visually marked button for emergency alarm is available
  • Tactile marking on button for emergency alarm is available
  • Alarm instructions in easy to understand Swedish are not available
  • Alarm instructions in braille are not available
  • Alarm instructions as picture symbols are available
  • A visual confirmation that the alarm has gone through is not available
  • An acoustic confirmation that the alarm has gone through is available
  • Emergency instructions in english are not available

Control panel in the lift

  • The upper row of buttons is placed 84cm from the floor
  • The lower row of buttons is placed 84cm from the floor
  • The distance between the manoeuvering panel and the corner by the door is 64cm
  • The manoeuvering panel is angled outward from wall from the wall
  • The lift button is angled outward from wall

Information about floors

  • Visual information is available regarding the floor levels
  • There is audible information in the lift regarding
  • Sign with information about businesses and activities is not available

Section heading

Print

Indoor environment

  • The sound environment is noise free
  • The sound has a short lingering note
  • The lighting is non-blinding
  • The lighting is even
  • Wall-to-wall textile carpet are not available
  • The evacuation alarm is audible, visual

Assistance dogs

  • Guide dog, Service dog, Signal dog is/are allowed in the space

Walking area

  • A walking area is
  • The walking area is 300cm wide
  • Space where it is possible to turn around is available
  • A walking area is
  • The walking area is 300cm wide
  • Some parts have a limited walking area that is 180 cm wide

Loose object in walking area

  • Loose object in pathway is available

Sign near door

  • The lower edge of the sign is placed 155cm from the ground
  • The upper edge of the sign is placed 141cm from the ground
  • Sign are available placed on door
  • Sign is not available placed next to door on the same side as the doorhandle
  • The brightness contrast of the sign is 0,85NCS against the background
  • The sign has neither relief nor braille
  • The size of capitals is 90mm

Swing door

  • The free width of the door opening is 180 cm
  • The door surface has a lightness contrast of 0,00NCS against the door frame
  • The door frame has a lightness contrast of 0,95NCS against the surrounding wall

Swing door opens only manually

  • The door handle is placed 87cm from the nearest obstacle
  • Door closer is available on the door

Gateway

  • The free width of the door opening is 200cm
  • The door frame has a lightness contrast of 0,00NCS against the surrounding wall

Section heading

Print

Sign on wall

  • The lower edge of the sign is placed 139cm from the ground
  • The upper edge of the sign is placed 157 cm from the ground
  • The brightness contrast of the sign is 0,95NCS against the background
  • Sign is available in relief
  • The brightness contrast of the sign is 0,95NCS against the background
  • Sign is available in relief
  • The brightness contrast of the sign is 0,95NCS against the background
  • The sign has relief, braille
  • The size of capitals is 20mm

Swing door

  • The turning space outside the door is 154cm wide
  • The length of the turning space outside the door is 300cm
  • The free width of the door opening is 87cm
  • The door surface has a lightness contrast of 0,85NCS against the door frame
  • The door frame has a lightness contrast of 0,85NCS against the surrounding wall
  • The door lock is one hold lock

Swing door opens manually

  • The door handle is placed 70,5cm from the nearest obstacle
  • Door closer is not available on the door
  • The pulling handle is placed horizontal
  • Centrally placed pulling handle available
  • The lenght of the pulling handle is 82cm
  • The pulling handle is placed 82cm above the floor

Design of the toilet for disabled

  • The width is 249,9cm
  • The length is 220cm
  • The free space on left side of toilet as seen from the front is 105,7cm wide
  • The free space on right side of toilet as seen from the front is 107,4cm wide
  • The seating height of the toilet is 47 cm
  • Seat made of a hard material is available
  • The toilet has a lightness contrast of 0,50NCS against the background
  • Shelf for unloading is not available
  • A container with lid is available that is large enough for stoma bags or adult nappies
  • The lower edge of the mirror is 89cm from the floor
  • The upper edge of the mirror is 200cm from the floor
  • The hook has a height of 134cm
  • The hook is placed 118 cm from corner
  • The soap is not perfumed
  • Changing table is not available
  • Air freshener or similar which gives off scent is not available
  • A means for drying your hands is available 90,5cm from the floor
  • Drying is placed 68 cm from corner
  • Drying is done with paper towel holder
  • Visual evacuation alarm available
  • Cleaning list is available
  • The frequency of cleaning is 5 times per week

Armrest on right hand side as seen from the front

  • The armrest is foldable
  • The height of the grab bar is 80 cm
  • Toilet paper holder on right grab bar as seen from the front is available

Armrest on left hand side as seen from the front

  • The armrest is foldable
  • The height of the grab bar is 80 cm
  • Toilet paper holder on left grab bar as seen from the front is not available

Armrests

  • The distance between the grab bars is 62 cm

Washbasin

  • The upper edge of the basin is 84,5cm from the floor
  • The centre of the drain pipe is placed 86cm from the side wall
  • Water seal and pipe drawn inside the wall, or to the side, are available
  • The basin has a lightness cotrast of 0,50NCS against its background
  • The basin has one handle mixer with lever

Emergency alarm

  • Emergency alarm using a light signal outside door is available
  • Emergency alarm using a sound signal outside the door is available
  • Emergency alarm which goes to a constantly manned reception, or similar, during opening hours is not available
  • Staff who have instructions for action in case of emergency are available
  • Door that can be unlocked from the outside without a special tool or key in case of emergency is available
  • Emergency alarm with switch on a cord is not available

Emergency alarm on wall

  • Lower emergency alarm on the wall is placed 20 cm from the floor
  • Higher emergency alarm on the wall is placed 71cm from the floor

Section heading

Print

Stairs

  • The stairs are compensated by nothing
  • There is 17st steps to the resting level
  • The stairs are straight
  • The stairs are 165,8cm wide
  • The bottom step has a contrast marking of 0,00NCS
  • The stair steps are 16,1cm high
  • The top step has a contrast marking of 0,00NCS
  • Depth of staircase steps is 30,6cm
  • There are not available protruding level steps
  • The staircase is hardened, even

Handrail on right hand side as seen from below

  • The height of the handrail is 912cm
  • The handrail extends 0cm past the part
  • Handrail stops 0cm before the bottom end
  • There available a handrail that ends abruptly at the lower part
  • There available a marking lower part at the end of handrail
  • The handrail extends 28cm past the part
  • The handrail ends 0cm before the top part
  • There available a handrail that ends abruptly at the upper part
  • There available a marker at the end of the handrail at the top
  • The brightness contrast of the handrail is 0,95NCS against the background
  • There available a handrail which runs continuously

Object sticks out into the stairs

  • There is 150,2cm of free space under the protruding object

Individual step

  • The height of the step is 19,7cm
  • The lightness contrast of the step is 0,70NCS against the background

Swing door

  • The turning space outside the door is 300cm wide
  • The length of the turning space outside the door is 300cm
  • The turning space outside the door tilts 0,00% sideways
  • The turning space outside the door tilts 0,00% lengthways
  • The free width of the door opening is 88cm
  • Lighting is available
  • The door surface has a lightness contrast of 0,00NCS against the door frame
  • The door frame has a lightness contrast of 0,70NCS against the surrounding wall
  • The turning space inside the door is 168cm wide
  • The length of the turning space inside the door is 337,4cm
  • The turning space inside the door tilts 0,3% sideways
  • The turning space inside the door tilts 1,9% lengthways
  • The door is always opened by staff, keycard or key
  • The free width of the door opening is 74 cm
  • The door surface has a lightness contrast of 0,00NCS against the door frame
  • The door frame has a lightness contrast of 0,85NCS against the surrounding wall

Threshold

  • The height of the threshold is 2cm
  • The height difference to the bevelling is 1cm

Doormat inside door

  • The doormat is inset level with ground

Runner inside door

  • The runner is loose

Threshold

  • The height of the threshold is 6cm
  • The height difference to the bevelling is 2cm
  • The door is always opened by staff, keycard or key

Entrance

  • Designated smoking area is available
  • A smoking area is available that is placed so that smoke is avoided inside the building and by the entrance

Section heading

Print

Sign on wall

  • The sign lighting is non-blinding
  • The lower edge of the sign is placed 253,6cm from the ground
  • The upper edge of the sign is placed 320,6cm from the ground
  • The brightness contrast of the sign is 0,70NCS against the background
  • Sign is not available in relief
  • The brightness contrast of the sign is 0,70NCS against the background
  • The sign has neither relief nor braille
  • The size of capitals is 200mm

Swing door

  • The turning space outside the door is 300cm wide
  • The length of the turning space outside the door is 300cm
  • The turning space outside the door tilts 0,0% sideways
  • The turning space outside the door tilts 0,0 % lengthways
  • The free width of the door opening is 180 cm
  • Lighting is available
  • The door surface has a lightness contrast of 0,00NCS against the door frame
  • The door frame has a lightness contrast of 0,85NCS against the surrounding wall
  • The turning space inside the door is 300cm wide
  • The length of the turning space inside the door is 300cm
  • The turning space inside the door tilts -0,2% sideways
  • The turning space inside the door tilts 0,0 % lengthways

Threshold

  • The height of the threshold is 2 cm

Swing door opens only manually

  • The door handle is placed 105cm from the nearest obstacle
  • Door closer is available on the door
  • Designated smoking area is available
  • A smoking area is available that is placed so that smoke is avoided inside the building and by the entrance

Section heading

Print

Swing door

  • The free width of the door opening is 86cm
  • The door surface has a lightness contrast of 0,00NCS against the door frame
  • The door frame has a lightness contrast of 0,85NCS against the surrounding wall
  • The free width of the door opening is 88cm
  • The free width of the door opening is 106cm
  • The door surface has a lightness contrast of 0,00NCS against the door frame
  • The door frame has a lightness contrast of 0,70NCS against the surrounding wall

Swing door opens only manually

  • The door handle is placed 87,3cm from the nearest obstacle
  • Door closer is available on the door

Indoor environment

  • The sound environment is noise free
  • The sound has a short lingering note
  • The lighting is non-blinding
  • The lighting is even
  • Means for screening off glaring daylight are not available
  • Wall-to-wall textile carpet are not available
  • The evacuation alarm is audible, visual

Assistance dogs

  • Guide dog, Service dog, Signal dog is/are allowed in the space

Walking area

  • A walking area is hardened, even, non-slippery
  • The walking area is 300cm wide
  • Space where it is possible to turn around is available
  • A walking area is hardened, non-slippery , even
  • The walking area is 300cm wide
  • Some parts have a limited walking area that is 167,1cm wide

Loose object in walking area

  • Loose object in pathway is available

Seat

  • The seating height of the seat is 47 cm
  • There is backrest available on the seat
  • Armrest is not available on the seat

Sign near door

  • The lower edge of the sign is placed 133cm from the ground
  • The upper edge of the sign is placed 165cm from the ground
  • Sign are available placed on door
  • Sign is not available placed next to door on the same side as the doorhandle
  • The brightness contrast of the sign is 0,50NCS against the background
  • The sign has neither relief nor braille
  • The size of capitals is 10 mm

Lift

  • The call button is placed 86cm above the ground
  • The distance to the nearest object is 91,5cm
  • The lightness contrast of the function is 0,80NCS against the background
  • The function is press button
  • The length of the free space is 223,2cm
  • The width of the free space is 189,6cm
  • The lift car is 148,7cm deep
  • The lift car is 100,8cm wide
  • The difference in level between the lift floor and the area outside is 0mm when the lift has stopped
  • Handrail is available on the same side as the control panel
  • The handrail has a lightness contrast of 0,70NCS
  • The handrail is 83cm above the floor
  • The seat is
  • Lift that opens out onto a descending staircase is not available

Door contrast

  • The door surface has a lightness contrast of 0,00NCS against the door frame
  • The door frame has a lightness contrast of 0,00NCS against the surrounding wall

Swing door opens with switch for door opener

  • The switch for the door opener outside the door is placed 87cm above the floor
  • The switch for the door opener outside the door is placed 106cm from the nearest obstacle
  • The switch for the door opener outside the door has a lightness contrast of 0,70NCS
  • Door which opens out into area where people pass is not available
  • Marking of the area covered by the door as it opens up, is not available that can be felt with a white cane
  • Security sensor is not available for when the door opens
  • Security sensor is not available for when the door closes
  • The passage time is 1160s

Control panel in lift

  • The lift buttons are 5 cm large
  • The type of lift buttons is raised
  • The lift buttons have neither relief nor braille as a tactile marking
  • Lift button available which needs to be held in for the duration of the ride
  • Emergency alarm that is placed on or next to the control panel are available
  • Visually marked button for emergency alarm is available
  • Tactile marking on button for emergency alarm is available
  • Alarm instructions in easy to understand Swedish are not available
  • Alarm instructions in braille are not available
  • Alarm instructions as picture symbols are available
  • A visual confirmation that the alarm has gone through is not available
  • An acoustic confirmation that the alarm has gone through is available
  • Emergency instructions in english are not available

Control panel in the lift

  • The upper row of buttons is placed 84cm from the floor
  • The lower row of buttons is placed 84cm from the floor
  • The distance between the manoeuvering panel and the corner by the door is 64cm
  • The manoeuvering panel is angled outward from wall from the wall
  • The lift button is angled outward from wall

Information about floors

  • Visual information is available regarding the floor levels
  • There is audible information in the lift regarding
  • Sign with information about businesses and activities is not available

Single colour marking on the glass surface at eye level for sitting

  • The marking is placed 85cm above the floor
  • The colour of the marking is grey
  • The marking is placed 85cm above the floor
  • The colour of the marking is
  • The other colour of the marking is
  • The lightness contrast between the colours of the marking is 0,00NCS

Large, single colour marking on glass pane

  • The lower edge of the marking is placed 82cm above the ground
  • The upper edge of the marking i placed 90cm above the ground
  • The colour of the marking is grey
  • The lower edge of the marking is placed 0 cm above the ground
  • The upper edge of the marking i placed 0cm above the ground
  • The colour of the marking is
  • The other colour of the marking is
  • The lightness contrast between the colours of the marking is 0,00NCS

Threshold

  • The height of the threshold is 3cm
  • The door is on request opened by staff, keycard or key

Section heading

Print

Swing door

  • The free width of the door opening is 75cm
  • The door surface has a lightness contrast of 0,00NCS against the door frame
  • The door frame has a lightness contrast of 0,85 NCS against the surrounding wall

Threshold

  • The height of the threshold is 2cm

Swing door opens only manually

  • The door handle is placed 300cm from the nearest obstacle
  • Door closer is not available on the door

Indoor environment

  • The sound environment is noise free
  • The sound has a short lingering note
  • The lighting is non-blinding
  • The lighting is even
  • Means for screening off glaring daylight are available
  • Wall-to-wall textile carpet are not available
  • The evacuation alarm is audible, visual

Assistance dogs

  • Guide dog, Service dog, Signal dog is/are allowed in the space

Walking area

  • A walking area is hardened, even
  • The walking area is 120cm wide
  • Space where it is possible to turn around is available
  • A walking area is hardened, even
  • The walking area is 300cm wide
  • Some parts have a limited walking area that is 162cm wide

Loose object in walking area

  • Loose object in pathway is available

Describe the common room

  • Hearing aid equipment is available in the room or area
  • Regular controls of the functionality of the hearing equipment are not available
  • Audio technical equipment is mobile inductive loop
  • Staff with knowledge of how to use the hearing equipment is available

Seat

  • The seating height of the seat is 48cm
  • There is backrest available on the seat
  • Armrest is not available on the seat

Table

  • The height of the free space under the table is 70cm
  • The height of the table top is 73cm from the floor
  • The free legroom under the table is 140cm deep
  • The free legroom under the table is 400cm wide

Section heading

Print

Swing door

  • The free width of the door opening is 106cm
  • The door surface has a lightness contrast of 0,00NCS against the door frame
  • The door frame has a lightness contrast of 0,70NCS against the surrounding wall

Single colour marking on the glass surface at eye level for sitting

  • The marking is placed 86cm above the floor
  • The colour of the marking is grey

Marking with several colours on the glass surface at eye level for sitting

  • The marking is placed 86cm above the floor
  • The colour of the marking is grey
  • The other colour of the marking is
  • The lightness contrast between the colours of the marking is 0,00NCS

Large, single colour marking on glass pane

  • The lower edge of the marking is placed 82cm above the ground
  • The upper edge of the marking i placed 90cm above the ground
  • The colour of the marking is grey
  • The lower edge of the marking is placed 82cm above the ground
  • The upper edge of the marking i placed 90cm above the ground
  • The colour of the marking is grey
  • The other colour of the marking is
  • The lightness contrast between the colours of the marking is 0,00NCS

Threshold

  • The height of the threshold is 2cm
  • The door is on request opened by staff, keycard or key

Indoor environment

  • The sound environment is noise free
  • The sound has a short lingering note
  • The lighting is non-blinding
  • The lighting is even
  • Means for screening off glaring daylight are not available
  • Wall-to-wall textile carpet are not available
  • The evacuation alarm is audible, visual

Assistance dogs

  • Guide dog, Service dog, Signal dog is/are allowed in the space

Walking area

  • A walking area is hardened, even
  • The walking area is 187,5cm wide
  • Space where it is possible to turn around is available
  • A walking area is even, hardened
  • The walking area is 187,5cm wide
  • Doors that may be opened up into the walking area are on the left side as seen from the front of the passage

Sign near door

  • The lower edge of the sign is placed 133cm from the ground
  • The upper edge of the sign is placed 165cm from the ground
  • Sign are available placed on door
  • Sign is not available placed next to door on the same side as the doorhandle
  • The brightness contrast of the sign is 0,50NCS against the background
  • The sign has neither relief nor braille
  • The size of capitals is 20mm

Gateway

  • The free width of the door opening is 189cm
  • The door frame has a lightness contrast of 0,00NCS against the surrounding wall

Section heading

Print

Swing door

  • The turning space outside the door is 300cm wide
  • The length of the turning space outside the door is 146cm
  • The free width of the door opening is 74 cm
  • The door surface has a lightness contrast of 0,00NCS against the door frame
  • The door frame has a lightness contrast of 0,70NCS against the surrounding wall
  • The door lock is one hold lock

Threshold

  • The height of the threshold is 2cm

Swing door opens manually

  • The door handle is placed 63cm from the nearest obstacle
  • Door closer is not available on the door
  • The pulling handle is placed horizontal
  • Centrally placed pulling handle available
  • The lenght of the pulling handle is 62cm
  • The pulling handle is placed 80cm above the floor

Design of the toilet for disabled

  • The width is 218,3cm
  • The length is 218,6cm
  • The free space on left side of toilet as seen from the front is 105cm wide
  • The free space on right side of toilet as seen from the front is 78cm wide
  • The seating height of the toilet is 50cm
  • Seat made of a hard material is available
  • The toilet has a lightness contrast of 0,10NCS against the background
  • Shelf for unloading is not available
  • A container with lid is available that is large enough for stoma bags or adult nappies
  • The lower edge of the mirror is 87cm from the floor
  • The upper edge of the mirror is 177cm from the floor
  • The hook has a height of 84 cm
  • The hook is placed 115cm from corner
  • The soap is not perfumed
  • Changing table is available
  • The height of the changing table is 87cm
  • The length of the changing table is 70cm
  • The changing table is 60cm wide
  • Air freshener or similar which gives off scent is not available
  • A means for drying your hands is available 132,7cm from the floor
  • Drying is placed 98,5cm from corner
  • Drying is done with paper towel holder
  • Visual evacuation alarm available
  • Cleaning list is available
  • The frequency of cleaning is 5 times per week

Armrest on right hand side as seen from the front

  • The armrest is foldable
  • The height of the grab bar is 70cm
  • Toilet paper holder on right grab bar as seen from the front is available

Armrest on left hand side as seen from the front

  • The armrest is foldable
  • The height of the grab bar is 70cm
  • Toilet paper holder on left grab bar as seen from the front is not available

Armrests

  • The distance between the grab bars is 64cm

Washbasin

  • The upper edge of the basin is 84cm from the floor
  • The centre of the drain pipe is placed 44cm from the side wall
  • Water seal and pipe drawn inside the wall, or to the side, are available
  • The basin has a lightness cotrast of 0,10NCS against its background
  • The basin has one handle mixer with lever

Emergency alarm

  • Emergency alarm using a light signal outside door is available
  • Emergency alarm using a sound signal outside the door is available
  • Emergency alarm which goes to a constantly manned reception, or similar, during opening hours is not available
  • Staff who have instructions for action in case of emergency are available
  • Door that can be unlocked from the outside without a special tool or key in case of emergency is available

Emergency alarm on electric cord

  • Emergency alarm with switch on a cord is available

Emergency alarm on wall

  • Lower emergency alarm on the wall is placed 23cm from the floor
  • Higher emergency alarm on the wall is placed 89cm from the floor

Section heading

Print

Workbench

  • The height of the space under the work surface is 87,5cm
  • The space under the work surface is 218 cm wide
  • The space under the work surface is 52cm deep
  • The length of the work surface is 310cm
  • The height of the work surface is 90,5cm
  • An electric socket is not available at the front edge of the work surface

Sink

  • The free height of the space under the sink is 0 cm
  • The free leg room under the sink is 0cm wide
  • Water seal and pipes that are drawn inside the wall or to the side, for leg room, are not available
  • The free space for legs under the sink is 0cm deep
  • The sink has one handle mixer with lever
  • The reachable height of the sink is 90,5cm

Hob

  • The height of the space under the hob is 0 cm
  • The width of the space under the hob is 0cm
  • The working height of the hob is 92cm
  • The depth of the space under the hob is 0cm
  • The distance between the hob and the nearest corner is 50,5cm
  • The controls on the hob are touch button
  • There are not available tactile markings on all hob controls
  • The controls have a brightness contrast of 0,10NCS against background
  • Unloading space near hob are available

Kitchen

  • The lighting is non-blinding
  • The lighting is even
  • The length of the free space is 300cm
  • The width of the free space is 300cm
  • Tactile markings are not available on all dishwasher controls
  • The dishwasher controls have a lightness contrast of 0,50NCS against background
  • Instructions for the dishwasher are not available in braille
  • Instructions for the dishwasher are not available in easy to read Swedsih
  • The distance between the dishwasher and the nearest corner is 101cm
  • The fridge is placed 111cm from the nearest corner
  • Unloading space near the fridge available
  • Oven door attached on side not available
  • There are available unloading space near oven
  • The centre of the oven is 60cm from the floor
  • Tactily marked oven controls not available
  • Oven controls against the background have 0,50NCS brightness contrast
  • Oven instructions in braille not available
  • The distance between the oven and the nearest corner is 41,5cm
  • Side hung oven door is available
  • Unloading surface near microwave oven is available
  • The centre of the microwave oven is 106cm above the floor
  • Tactile markings on all microwave oven controls are not available
  • The microwave oven controls have a brightness contrast of 0,00NCS against background
  • The distance between the microwave oven and the nearest corner is 97cm
  • Instructions for microwave oven in braille are not available
  • Instructions for microwave in easy to read Swedish are not available
  • Handles on drawers and cabinets easy to grasp available
  • The brightness contrast of the handle is 0,35NCS against background

Section heading

Print

Gateway

  • The free width of the door opening is 187,1cm
  • The door frame has a lightness contrast of 0,00NCS against the surrounding wall

Threshold

  • The height of the threshold is 3cm
  • The height of the threshold is 3cm

Indoor environment

  • The sound environment is noise free
  • The sound has a short lingering note
  • The lighting is non-blinding
  • The lighting is even
  • Wall-to-wall textile carpet are not available
  • The evacuation alarm is audible, visual

Assistance dogs

  • Guide dog, Service dog, Signal dog is/are allowed in the space

Walking area

  • A walking area is hardened, even, non-slippery
  • The walking area is 187,2cm wide
  • Space where it is possible to turn around is available
  • A walking area is hardened, even
  • The walking area is 290cm wide

Swing door

  • The free width of the door opening is 78cm
  • The door surface has a lightness contrast of 0,00NCS against the door frame
  • The door frame has a lightness contrast of 0,85NCS against the surrounding wall

Swing door opens only manually

  • The door handle is placed 80cm from the nearest obstacle
  • Door closer is not available on the door

Section heading

Print

Swing door

  • The free width of the door opening is 78cm
  • The door surface has a lightness contrast of 0,00NCS against the door frame
  • The door frame has a lightness contrast of 0,85NCS against the surrounding wall

Threshold

  • The height of the threshold is 3cm

Swing door opens only manually

  • The door handle is placed 80cm from the nearest obstacle
  • Door closer is not available on the door

Indoor environment

  • The sound environment is noise free
  • The sound has a short lingering note
  • The lighting is non-blinding
  • The lighting is even
  • Wall-to-wall textile carpet are not available
  • The evacuation alarm is audible, visual

Assistance dogs

  • Guide dog, Service dog, Signal dog is/are allowed in the space

Walking area

  • A walking area is hardened, even
  • The walking area is 300cm wide
  • Space where it is possible to turn around is available
  • A walking area is hardened, even
  • The walking area is 300cm wide
  • Some parts have a limited walking area that is 280cm wide

Loose object in walking area

  • Loose object in pathway is available

Describe the common room

  • Hearing aid equipment is available in the room or area
  • Regular controls of the functionality of the hearing equipment are not available
  • Audio technical equipment is mobile inductive loop
  • Staff with knowledge of how to use the hearing equipment is available

Seat

  • The seating height of the seat is 48cm
  • There is backrest available on the seat
  • Armrest is not available on the seat

Table

  • The height of the free space under the table is 72,2cm
  • The height of the table top is 74,7cm from the floor
  • The free legroom under the table is 80cm deep
  • The free legroom under the table is 140cm wide

Drop-off and pick-up area with footpath (utanför Culturen)

Skriv ut

Drop-off and pick-up area

Parking and footpath (utanför Culturen)

Skriv ut

Freestanding or lined up parking space for disabled

Freestanding or lined up parking space for disabled

Entrance (Huvudentré Culturen)

Skriv ut

Swing door

Swing door

Single colour marking on the glass surface at eye level for sitting

Marking with several colours on the glass surface at eye level for sitting

Large, single colour marking on glass pane

Wide marking with several colours on glass pane

Wiping grid outside door

Threshold

Runner inside door

Swing door opens only manually

Swing door opens with switch for door opener

Swing door opens with switch for door opener

Entrance

Seat

Swing door in inner entrance

Swing door in inner entrance

Single colour marking on the glass surface at eye level for sitting

Marking with several colours on the glass surface at eye level for sitting

Single colour marking on the glass surface at eye level when standing

Markings with several colours on the glass surface at eye level for standing

Swing door in inner entrance opens manually

Swing door in inner entrance opens with switch for door opener

Swing door in inner entrance opens with switch for door opener

Indoor environment

Assistance dogs

Walking area

Walking area

Sign on wall

Stairs

Stairs

Handrail on right hand side as seen from below

Handrail on left hand side as seen from below

Lift

Lift

Lift

Lift

Swing door

Door contrast

Swing door opens manually

Swing door opens with switch for door opener

Control panel in lift

Control panel in the lift

Information about floors

Passage ( från huvudentrén till hiss vån BV)

Skriv ut

Indoor environment

Assistance dogs

Walking area

Walking area

Loose object in walking area

Sign near door

Swing door

Swing door opens only manually

Gateway

Toilet for disabled (vån BV)

Skriv ut

Sign on wall

Swing door

Swing door

Swing door opens manually

Swing door opens manually

Design of the toilet for disabled

Design of the toilet for disabled

Design of the toilet for disabled

Design of the toilet for disabled

Design of the toilet for disabled

Armrest on right hand side as seen from the front

Armrest on left hand side as seen from the front

Armrests

Washbasin

Washbasin

Emergency alarm

Emergency alarm on wall

Emergency alarm on wall

Entrance (Sidoentrè Culturen)

Skriv ut

Stairs

Stairs

Handrail on right hand side as seen from below

Object sticks out into the stairs

Individual step

Swing door

Swing door

Threshold

Doormat inside door

Runner inside door

Swing door

Threshold

Entrance

Entrance ( ABF vån 2)

Skriv ut

Sign on wall

Sign on wall

Swing door

Swing door

Threshold

Swing door opens only manually

Passage (från hiss - vån 2)

Skriv ut

Swing door

Swing door opens only manually

Indoor environment

Assistance dogs

Walking area

Walking area

Loose object in walking area

Seat

Sign near door

Lift

Lift

Lift

Swing door

Door contrast

Swing door opens with switch for door opener

Control panel in lift

Control panel in the lift

Information about floors

Swing door

Single colour marking on the glass surface at eye level for sitting

Large, single colour marking on glass pane

Threshold

Studierum (Lilla Konferensen vån 2)

Skriv ut

Swing door

Threshold

Swing door opens only manually

Indoor environment

Assistance dogs

Walking area

Walking area

Loose object in walking area

Describe the common room

Seat

Table

Passage (från ABF:s entré till kök och handikapptoalett - vån 2)

Skriv ut

Swing door

Single colour marking on the glass surface at eye level for sitting

Marking with several colours on the glass surface at eye level for sitting

Large, single colour marking on glass pane

Threshold

Indoor environment

Assistance dogs

Walking area

Walking area

Sign near door

Gateway

Toilet for disabled (vån 2 )

Skriv ut

Swing door

Swing door

Threshold

Swing door opens manually

Swing door opens manually

Design of the toilet for disabled

Design of the toilet for disabled

Design of the toilet for disabled

Design of the toilet for disabled

Design of the toilet for disabled

Armrest on right hand side as seen from the front

Armrest on left hand side as seen from the front

Armrests

Washbasin

Washbasin

Emergency alarm

Emergency alarm on electric cord

Emergency alarm on wall

Emergency alarm on wall

Kitchen section (vån 2 )

Skriv ut

Workbench

Sink

Hob

Kitchen

Kitchen

Kitchen

Passage (från kök till stora konferensen vån 2)

Skriv ut

Gateway

Threshold

Indoor environment

Assistance dogs

Walking area

Walking area

Swing door

Threshold

Swing door opens only manually

Studierum (Stora Konferensen vån 2)

Skriv ut

Swing door

Threshold

Swing door opens only manually

Indoor environment

Assistance dogs

Walking area

Walking area

Loose object in walking area

Describe the common room

Seat

Table