Denna webbplats använder teknik som troligen inte stöds i din webbläsare, därför kan vissa saker se konstiga ut eller inte fungera. Vi rekommenderar att du byter till en modern webbläsare istället.
Skip to main content

Försäkringskassan Servicekontor

Hoppa över karta

Contact

Uppdated
3/2/2016 9:25:09 AM
Address
Slottsgatan 10
703 61
Örebro
Telephone
+46 0771-524524
Email
Views

Related facilities

Filter on your needs

Description of the site you are visiting

Skriv ut hela anläggningen

Section heading

Print

Freestanding or lined up parking space for disabled

  • The disabled parking space is marked by sign with symbol
  • The disabled parking space is 2.4m wide
  • The lengthways tilt of the disabled parking space is 3.1%
  • The surface of the disabled parking space is hardened, even
  • The disbaled parking space tilts 1% sideways
  • The disabled parking space is 43m from the entrance
  • Lighting not available
  • Tactile trail is not available

Footpath

  • The pedestrian path is 3.4m wide
  • The surface of the pedestrian path is hardened, even
  • The walking area tilts 2.9% sideways
  • Lighting is not available
  • Uncovered gutter is not available
  • The hard and smooth walking surface is 2.25m wide
  • Armrest is not available on the seat

Individual step

  • The height of the step is 3,4cm
  • The lightness contrast of the step is 0NCS against the background

Section heading

Print

Sign on wall

  • The sign lighting is non-blinding
  • The lower edge of the sign is placed 334cm from the ground
  • The upper edge of the sign is placed 364cm from the ground
  • The brightness contrast of the sign is 0.8NCS against the background
  • The sign has neither relief nor braille
  • The size of capitals is 200mm

Sign near door

  • The lower edge of the sign is placed 122cm from the ground
  • The upper edge of the sign is placed 179cm from the ground
  • Sign are available placed on door
  • Sign is available placed next to door on the same side as the doorhandle
  • The brightness contrast of the sign is 0.8NCS against the background
  • The sign has neither relief nor braille
  • The size of capitals is 10mm

Swing door

  • The turning space outside the door is 300cm wide
  • The length of the turning space outside the door is 0cm
  • The turning space outside the door tilts 0% sideways
  • The turning space outside the door tilts 0% lengthways
  • The free width of the door opening is 97cm
  • Lighting is available
  • The door surface has a lightness contrast of 0NCS against the door frame
  • The door frame has a lightness contrast of 0.40NCS against the surrounding wall
  • The turning space inside the door is 242cm wide
  • The length of the turning space inside the door is 225cm
  • The turning space inside the door tilts 0% sideways
  • The turning space inside the door tilts 0.8% lengthways

Single colour marking on the glass surface at eye level for sitting

  • The marking is placed 95cm above the floor
  • The colour of the marking is brown
  • The marking is placed 95cm above the floor
  • The colour of the marking is grey

Threshold

  • The height of the threshold is 2cm
  • The height difference to the bevelling is 0cm
  • The height of the threshold is 3cm
  • The height difference to the bevelling is 2cm

Wiping grid inside door

  • The wiping grid is inset level with ground

Swing door opens only manually

  • The door handle is placed 102cm from the nearest obstacle
  • Door closer is available on the door

Swing door opens with switch for door opener

  • The switch for the door opener outside the door is placed 90cm above the floor
  • The switch for the door opener outside the door is placed 0cm from the nearest obstacle
  • The switch for the door opener outside the door has a lightness contrast of 0.3NCS
  • Door which opens out into area where people pass is not available
  • Marking of the area covered by the door as it opens up, is not available that can be felt with a white cane
  • Security sensor is not available for when the door opens
  • Security sensor is not available for when the door closes
  • The passage time is 10s
  • The switch for the door opener inside the door is placed 88cm above the floor
  • The switch for the door opener inside the door is placed 128cm from the nearest obstacle
  • The switch for the door opener inside the door has a lightness contrast of 0.4NCS
  • Designated smoking area is not available
  • A smoking area is not available that is placed so that smoke is avoided inside the building and by the entrance

Swing door in inner entrance

  • The turning space outside the door is 242cm wide
  • The length of the turning space outside the door is 225cm
  • The turning space outside the door tilts 0% sideways
  • The turning space outside the door tilts 0.8% lengthways
  • The free width of the door opening is 100cm
  • Lighting is available
  • The door surface has a lightness contrast of 0NCS against the door frame
  • The door frame has a lightness contrast of 0.40NCS against the surrounding wall
  • The turning space inside the door is 248cm wide
  • The length of the turning space inside the door is 730cm
  • The turning space inside the door tilts 0.2% sideways
  • The turning space inside the door tilts 3.9% lengthways

Swing door in inner entrance opens manually

  • The door handle is placed 85cm from the nearest obstacle
  • Door closer is available on the door

Swing door in inner entrance opens with switch for door opener

  • The switch for the door opener outside the door is placed 89cm above the floor
  • The switch for the door opener outside the door is placed 72cm from the nearest obstacle
  • The switch for the door opener outside the door has a lightness contrast of 0.3NCS
  • Door which opens out into area where people pass is not available
  • Marking of the area covered by the door as it opens up, is not available that can be felt with a white cane
  • Security sensor is not available for when the door opens
  • Security sensor is not available for when the door closes
  • The passage time is 10s
  • The switch for the door opener inside the door is placed 86cm above the floor
  • The switch for the door opener inside the door is placed 37cm from the nearest obstacle
  • The switch for the door opener inside the door has a lightness contrast of 0.3NCS

Section heading

Print

Swing door

  • The free width of the door opening is 82cm
  • The door surface has a lightness contrast of 0NCS against the door frame
  • The door frame has a lightness contrast of 0.4NCS against the surrounding wall
  • The turning space outside the door is 150cm wide
  • The length of the turning space outside the door is 300cm
  • The free width of the door opening is 91cm
  • The door surface has a lightness contrast of 0.4NCS against the door frame
  • The door frame has a lightness contrast of 0NCS against the surrounding wall
  • The door lock is one hold lock

Single colour marking on the glass surface at eye level for sitting

  • The marking is placed 95cm above the floor
  • The colour of the marking is brown

Swing door opens only manually

  • The door handle is placed 91cm from the nearest obstacle
  • Door closer is available on the door

Swing door opens with switch for door opener

  • The switch for the door opener outside the door is placed 85cm above the floor
  • The switch for the door opener outside the door is placed 356cm from the nearest obstacle
  • The switch for the door opener outside the door has a lightness contrast of 0.3NCS
  • Door which opens out into area where people pass is not available
  • Marking of the area covered by the door as it opens up, is not available that can be felt with a white cane
  • Security sensor is not available for when the door opens
  • Security sensor is not available for when the door closes
  • The passage time is 10s
  • The switch for the door opener inside the door is placed 86cm above the floor
  • The switch for the door opener inside the door is placed 40cm from the nearest obstacle
  • The switch for the door opener inside the door has a lightness contrast of 0.35NCS
  • The door is not at all opened by staff

Indoor environment

  • The sound environment is noisy
  • The sound has a short lingering note
  • The lighting is non-blinding
  • The lighting is even
  • Cleaning products are not perfumed
  • The room is cleaned 5 per week
  • Wall-to-wall textile carpet are not available
  • The evacuation alarm is audible, visual
  • Guide dog, Service dog, Signal dog is/are allowed in the space

Walking area

  • A walking area is hardened, even
  • The walking area is 195cm wide
  • Space where it is possible to turn around is not available

Seat

  • The seating height of the seat is 47cm
  • There is backrest available on the seat
  • Armrest is available on the seat

Table

  • The height of the free space under the table is 108cm
  • The height of the table top is 110cm from the floor
  • The free legroom under the table is 30cm deep
  • The free legroom under the table is 70cm wide
  • Tactile trail is not available

Counter with fixed height

  • The height of the counter is 114cm
  • The length of the counter is 140cm
  • The depth of the legroom is 60cm
  • Well lit reception is available
  • The lightness contrast of the counter is 0.3NCS against the background
  • Hearing aid equipment is not available in the room or area
  • Regular controls of the functionality of the hearing equipment are not available
  • Staff with knowledge of how to use the hearing equipment is not available
  • Special aids or equipment are not available
  • Staff that have knowledge regarding existing aids and equipment, and how they are used, is not available
  • Video phone is not available
  • Rutines for interpreter are available
  • Seperate space/waiting area for interpreter is not available
  • Access to assistance is not available

Toilet for disabled

  • The type of toilet is one toilet in the space

Swing door opens manually

  • The door handle is placed 124cm from the nearest obstacle
  • Door closer is available on the door

Design of the toilet for disabled

  • The width is 222cm
  • The length is 280cm
  • The free space on left side of toilet as seen from the front is 190cm wide
  • The free space on right side of toilet as seen from the front is 52cm wide
  • The seating height of the toilet is 49cm
  • Seat made of a hard material is available
  • The toilet has a lightness contrast of 0.3NCS against the background
  • Shelf for unloading is not available
  • A container with lid is available that is large enough for stoma bags or adult nappies
  • The lower edge of the mirror is 96cm from the floor
  • The upper edge of the mirror is 181cm from the floor
  • The hook has a height of 160cm
  • The hook is placed 92cm from corner
  • The soap is not perfumed
  • The height of the changing table is 92cm
  • The length of the changing table is 66cm
  • The changing table is 53cm wide
  • Air freshener or similar which gives off scent is not available
  • A means for drying your hands is available 98cm from the floor
  • Drying is placed 14cm from corner
  • Drying is done with paper towel holder
  • Visual evacuation alarm available
  • Cleaning list is not available
  • The frequency of cleaning is 5 times per week
  • Tactile trail is not available

Armrest on right hand side as seen from the front

  • The armrest is foldable
  • The height of the grab bar is 73cm

Armrest on left hand side as seen from the front

  • The armrest is foldable
  • The height of the grab bar is 73cm

Armrests

  • The distance between the grab bars is 55cm

Washbasin

  • The upper edge of the basin is 81cm from the floor
  • The centre of the drain pipe is placed 91cm from the side wall
  • Water seal and pipe drawn inside the wall, or to the side, are available
  • The basin has a lightness cotrast of 0.3NCS against its background
  • The basin has one handle mixer with lever

Emergency alarm

  • Emergency alarm using a light signal outside door is available
  • Emergency alarm using a sound signal outside the door is available
  • Emergency alarm which goes to a constantly manned reception, or similar, during opening hours is available
  • Staff who have instructions for action in case of emergency are available
  • Door that can be unlocked from the outside without a special tool or key in case of emergency is not available

Emergency alarm on wall

  • Lower emergency alarm on the wall is placed 16cm from the floor
  • Higher emergency alarm on the wall is placed 66cm from the floor
  • Higher emergency alarm on the wall is placed 67cm from the floor

Counter with adjustable height

  • The length of the counter is 160cm
  • The depth of the legroom is 80cm
  • Well lit reception is available
  • The lowest height of the reception counter is 59cm
  • The highest height of the counter is 125cm
  • The lightness contrast of the counter is 0.3NCS against the background
  • Hearing aid equipment is not available in the room or area
  • Special aids or equipment are not available
  • Rutines for interpreter are available
  • Seperate space/waiting area for interpreter is not available
  • Access to assistance is available
  • Tactile trail is not available
  • The length of the counter is 160cm
  • The depth of the legroom is 80cm
  • Well lit reception is available
  • The lowest height of the reception counter is 59cm
  • The highest height of the counter is 125cm
  • The lightness contrast of the counter is 0.3NCS against the background
  • Hearing aid equipment is not available in the room or area
  • Special aids or equipment are not available
  • Rutines for interpreter are available
  • Seperate space/waiting area for interpreter is not available
  • Access to assistance is available

Section heading

Print

Swing door

  • The free width of the door opening is 76cm
  • The door surface has a lightness contrast of 0NCS against the door frame
  • The door frame has a lightness contrast of 0NCS against the surrounding wall

Swing door opens only manually

  • The door handle is placed 106cm from the nearest obstacle
  • Door closer is not available on the door
  • The door is always opened by staff

Indoor environment

  • The sound environment is noise free
  • The sound has a short lingering note
  • The lighting is non-blinding
  • The lighting is even
  • Means for screening off glaring daylight are available
  • Cleaning products are not perfumed
  • The room is cleaned 5 per week
  • Wall-to-wall textile carpet are not available
  • Guide dog, Service dog, Signal dog is/are allowed in the space

Walking area

  • A walking area is hardened, even
  • The walking area is 117cm wide
  • Space where it is possible to turn around is not available

Seat

  • The seating height of the seat is 47cm
  • There is backrest available on the seat
  • Armrest is available on the seat

Table with adjustable height

  • The lowest height of the adjustable table is 63cm
  • The leg room is 55cm wide
  • The highest height of the adjustable table is 127cm
  • Hearing aid equipment is not available in the room or area

Parking and footpath

Skriv ut

Freestanding or lined up parking space for disabled

Footpath

Individual step

Entrance

Skriv ut

Sign on wall

Sign near door

Swing door

Swing door

Single colour marking on the glass surface at eye level for sitting

Threshold

Wiping grid inside door

Swing door opens only manually

Swing door opens with switch for door opener

Swing door opens with switch for door opener

Swing door in inner entrance

Swing door in inner entrance

Single colour marking on the glass surface at eye level for sitting

Threshold

Swing door in inner entrance opens manually

Swing door in inner entrance opens with switch for door opener

Swing door in inner entrance opens with switch for door opener

Reception hall

Skriv ut

Swing door

Single colour marking on the glass surface at eye level for sitting

Swing door opens only manually

Swing door opens with switch for door opener

Swing door opens with switch for door opener

Indoor environment

Walking area

Seat

Table

Counter with fixed height

Toilet for disabled

Swing door

Swing door

Swing door opens manually

Design of the toilet for disabled

Design of the toilet for disabled

Design of the toilet for disabled

Armrest on right hand side as seen from the front

Armrest on left hand side as seen from the front

Armrests

Washbasin

Emergency alarm

Emergency alarm on wall

Emergency alarm on wall

Counter with adjustable height

Counter with adjustable height

Meeting room

Skriv ut

Swing door

Swing door opens only manually

Indoor environment

Walking area

Seat

Table with adjustable height